ABB ACSM1 Firmware Manual page 105

Motion control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

10.02 EXT1 START IN1
Selects the source 1 for the start and stop commands in external control location EXT1. See
parameter
10.01 EXT1 START FUNC
Note: This parameter cannot be changed while the drive is running.
Bit pointer: Group, index and bit
10.03 EXT1 START IN2
Selects the source 2 for the start and stop commands in external control location EXT1. See
parameter
10.01 EXT1 START FUNC
Note: This parameter cannot be changed while the drive is running.
Bit pointer: Group, index and bit
10.04 EXT2 START FUNC
Selects the source for the start and stop control in external control location EXT2.
Note: This parameter cannot be changed while the drive is running.
(0) NOT SEL
(1) IN1
(2) 3-WIRE
(3) FBA
(4) D2D
(5) IN1F IN2R
FW block:
DRIVE LOGIC
selections
(1) IN1
FW block:
DRIVE LOGIC
selection
(2)
3-WIRE.
FW block:
DRIVE LOGIC
No source selected.
Source of the start and stop commands are selected by parameter
10.05 EXT2 START
IN1. The start/stop is controlled as follows:
Par.
10.05
Command
0 -> 1
Start
1 -> 0
Stop
Source of the start and stop commands are selected by parameters
10.05 EXT2 START IN1
and
controlled as follows:
Par.
10.05
Par.
10.06
0 -> 1
1
Any
1 -> 0
Any
0
Start and stop control from the source selected by parameter
CW
USED.
Start and stop control from another drive via D2D Control Word.
The source selected by
10.05 EXT2 START IN1
signal, the source selected by
start signal.
Par.
10.05
Par.
10.06
0
0
1
0
0
1
1
1
(see above)
and
(2)
3-WIRE.
(see above)
(see above)
10.06 EXT2 START
IN2. The start/stop is
Command
Start
Stop
Stop
is the forward start
10.06 EXT2 START IN2
Command
Stop
Start forward
Start reverse
Stop
Parameters and firmware blocks
105
10.13 FB
is the reverse

Advertisement

Table of Contents
loading

Table of Contents