12.09 DIO3 F MIN
Defines the minimum value for frequency output (when
OUTPUT).
3...32768 Hz
12.10 DIO3 F MAX SCALE
Defines the real value that corresponds to the maximum frequency output value defined by
parameter
12.08
12.09
0...32768
12.11 DIO3 F MIN SCALE
Defines the real value that corresponds to the minimum frequency output value defined by
parameter
0...32768
Firmware block:
RO
(5)
Connects an actual signal to the relay
output. The block also shows the
relay output status.
Block outputs located in other
parameter groups
12.12 RO1 OUT PTR
Selects a drive signal to be connected to relay output RO1.
Bit pointer: Group, index and bit
Firmware block:
DI
(4)
Shows the status of the digital inputs.
Inverts the status of any DI if desired.
Block outputs located in other
parameter groups
Parameters and firmware blocks
FW block:
Minimum DIO3 output frequency.
FW block:
12.08 DIO3 F
MAX.
DIO3 (Hz)
DIO3 (real)
12.11
12.10
Real value corresponding to value of parameter 12.08.
FW block:
12.09 DIO3 F
MIN. See parameter
Real value corresponding to value of parameter 12.09.
[ BRAKE COMMAND.0 ]
(4 / 3.15.0)
2.02 RO STATUS
FW block:
[ 00 0000 ]
2.01 DI STATUS
DIO3
(see above)
12.03 DIO3 CONF
DIO3
(see above)
DIO3 (Hz)
12.08
12.09
12.10
12.11
DIO3
(see above)
12.10 DIO3 F MAX
RO
TLF7 2 msec
2.02 RO STATUS
< 12.12 RO1 OUT PTR
(page 80)
RO
(see above)
DI
TLF7 2 msec
2.01 DI STATUS
12.13 DI INVERT MASK
(page 80)
is set to
(2) FREQ
DIO3 (real)
SCALE.
17
(2)
16
(1)