Group 51 Fba Settings - ABB ACSM1 Firmware Manual

Motion control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

Group
51 FBA SETTINGS
Further fieldbus communication configuration. These parameters need to be set only
if a fieldbus adapter module is installed. See also
page 385.
Notes:
• This parameter group is presented in the User's Manual of the fieldbus adapter as
parameter group 1 or A.
• The new settings will take effect when the drive is powered up the next time
(before powering off the drive, wait at least 1 minute), or when parameter
FBA PAR REFRESH
51
51 FBA SETTINGS
51.01 FBA TYPE
Displays the type of the connected fieldbus adapter module.
NOT DEFINED
(1)
(32)
(37)
51.02 FBA PAR2
...
....
51.26 FBA PAR26
Parameters 51.02...51.26 are adapter module-specific. For more information, see the User's Manual
of the fieldbus adapter module. Note that not all of these parameters are necessarily visible.
51.27 FBA PAR REFRESH
Validates any changed adapter module configuration parameter settings. After refreshing, the value
reverts automatically to
Note: This parameter cannot be changed while the drive is running.
(0) DONE
(1) REFRESH
51.28 PAR TABLE VER
Displays the parameter table revision of the fieldbus adapter module mapping file stored in the
memory of the drive.
In format xyz, where x = major revision number; y = minor revision number; z = correction number.
is activated.
FW block: None
Fieldbus adapter module not found (not properly connected, or
disabled by parameter
FPBA-xx PROFIBUS-DP adapter module.
FCAN-xx CANopen adapter module.
FDNA-xx DeviceNet adapter module.
FW block: None
....
FW block: None
FW block: None
(0)
DONE.
Refreshing done.
Refreshing.
FW block: None
Appendix A – Fieldbus control
50.01 FBA
ENABLE).
Parameters and firmware blocks
183