Mitsubishi Electric FR-A800 Series Instruction Manual page 200

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Function
Pr.
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1499
Pr.CLR
ALL.CL
Err.CL
Pr.CPY
Pr.CHG
IPM
AUTO
Pr.MD
*1
Differs according to the capacity.
6%: FR-A820-00077(0.75K) or lower, FR-A840-00038(0.75K) or lower
4%: FR-A820-00105(1.5K) to FR-A820-00250(3.7K), FR-A840-00052(1.5K) to FR-A840-00126(3.7K)
3%: FR-A820-00340(5.5K), FR-A820-00490(7.5K), FR-A840-00170(5.5K), FR-A840-00250(7.5K)
2%: FR-A820-00630(11K) to FR-A820-03160(55K), FR-A840-00310(11K) to FR-A840-01800(55K)
1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K) or higher
*2
The setting range or initial value for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
*3
The setting range or initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
*4
The initial value for the FR-A820-00490(7.5K) or lower and FR-A840-00250(7.5K) or lower.
*5
The initial value for the FR-A820-00630(11K) or higher and FR-A840-00310(11K) or higher.
*6
Differs according to the capacity.
4%: FR-A820-00490(7.5K) or lower, FR-A840-00250(7.5K) or lower
2%: FR-A820-00630(11K) to FR-A820-03160(55K), FR-A840-00310(11K) to FR-A840-01800(55K)
1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K) or higher
*7
The value for the 200 V class.
*8
The value for the 400 V class.
*9
The setting is available only when a plug-in option that supports Vector control is installed. For the corresponding parameters of each option, refer
to the detail page.
*10 The parameter number in parentheses is that used (displayed) on the LCD operation panel and the parameter unit.
*11 The setting range or initial value for the standard model.
*12 The setting range or initial value for the separated converter type.
*13 The setting range or initial value for the IP55 compatible model.
*14 The setting is available for the standard structure model.
*15 The setting is available for the standard structure model and the IP55 compatible model.
*16 The setting is available when the PLC function is enabled.
Downloaded from
ManualsNet.com
Pr.
Name
group
Load characteristics
H520
measurement mode
Load characteristics load
H521
reference 1
Load characteristics load
H522
reference 2
Load characteristics load
H523
reference 3
Load characteristics load
H524
reference 4
Load characteristics load
H525
reference 5
Load characteristics
H526
maximum frequency
Load characteristics
H527
minimum frequency
Upper limit warning detection
H531
width
Lower limit warning
H532
detection width
Upper limit fault detection
H533
width
Lower limit fault detection
H534
width
Load status detection signal
H535
delay time / load reference
measurement waiting time
E415
Parameter for manufacturer setting. Do not set.
Parameter clear
All parameter clear
Fault history clear
Parameter copy
Initial value change list
IPM initialization
Automatic parameter setting
Group parameter setting
search engine
Minimum
Setting range
setting
increments
0, 1 (2 to 5, 81 to 85)
1
0 to 400%, 8888, 9999 0.1%
0 to 400%, 8888, 9999 0.1%
0 to 400%, 8888, 9999 0.1%
0 to 400%, 8888, 9999 0.1%
0 to 400%, 8888, 9999 0.1%
0 to 590 Hz
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 400%, 9999
0.1%
0 to 400%, 9999
0.1%
0 to 400%, 9999
0.1%
0 to 400%, 9999
0.1%
0 to 60 s
0.1 s
(0), 1
1
(0), 1
1
(0), 1
1
(0), 1 to 3
1
1
0, 3003
1
(0), 1, 2
1
Initial value
Refer
Customer
to page
setting
FM
CA
0
439
9999
439
9999
439
9999
439
9999
439
9999
439
60 Hz 50 Hz
439
6 Hz
439
20%
439
20%
439
9999
439
9999
439
1 s
439
0
743
0
743
0
774
0
744
0
751
0
230
350
0
201
5. PARAMETERS
5.1 Parameter list
1
2
3
4
5
6
7
8
9
10
199