Mitsubishi Electric FR-A800 Series Instruction Manual page 208

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Pr. group
Pr.
M461
151
M462
152
M463
153
M464
167
M470
864
M500
495
M501
496
M502
497
M510
76
M520
799
M530
655
M531
656
M532
657
M533
658
M534
659
M600
863
M601
413
M610
635
M611
636
M612
637
M613
638
 T: Multi-function input terminal
parameters
Parameters for the setting of the input terminals via which
commands are given to the inverter.
Pr. group
Pr.
T000
73
T001
267
T002
74
T003
822
T004
826
T005
832
T006
836
T007
849
T010
868
T021
242
T022
125
T040
858
T041
243
Downloaded from
ManualsNet.com
Name
Output current detection
signal delay time
Zero current detection level
Zero current detection time
Output current detection
operation selection
Torque detection
Remote output selection
Remote output data 1
Remote output data 2
Fault code output selection
Pulse increment setting for
output power
Analog remote output
selection
Analog remote output 1
Analog remote output 2
Analog remote output 3
Analog remote output 4
Control terminal option-
*1
Encoder pulse division ratio
*1
Encoder pulse division ratio
Cumulative pulse clear signal
*1
selection
Cumulative pulse division
*1
scaling factor
Control terminal option-
*1
Cumulative pulse division
scaling factor
*1
Cumulative pulse storage
Name
Analog input selection
Terminal 4 input selection
Input filter time constant
Speed setting filter 1
Torque setting filter 1
Speed setting filter 2
Torque setting filter 2
Analog input offset adjustment
Terminal 1 function
assignment
Terminal 1 added
compensation amount
(terminal 2)
Terminal 2 frequency setting
gain frequency
Simple
Simple
Simple
Terminal 4 function
assignment
Terminal 1 added
compensation amount
(terminal 4)
search engine
Refer
Pr. group
Pr.
to page
487
T042
126
487
T050
252
487
T051
253
T052
573
487
T053
777
488
489
T054
778
489
C12
T100
489
*2
(917)
492
C13
T101
*2
(917)
493
C14
T102
*2
490
(918)
C15
490
T103
*2
(918)
490
C16
490
T110
*2
(919)
490
C17
T111
495
*2
(919)
C18
495
T112
*2
(920)
321
C19
T113
*2
(920)
321
C2
T200
*2
(902)
321
C3
T201
*2
(902)
321
125
T202
*2
(903)
C4
T203
*2
(903)
C5
T400
*2
(904)
C6
T401
*2
(904)
Refer
126
to page
T402
*2
(905)
496,
501
C7
T403
*2
496
(905)
503
C38
T410
*2
503
(932)
503
C39
T411
*2
503
(932)
503
C40
T412
*2
503
(933)
245,
C41
T413
431,
*2
(933)
500
T700
178
501
T701
179
T702
180
505
T703
181
245,
T704
182
431,
T705
183
500
T706
184
501
T707
185
Name
Terminal 4 frequency setting
gain frequency
Simple
Simple
Simple
Override bias
Override gain
4 mA input check selection
4 mA input fault operation
frequency
4 mA input check filter
Terminal 1 bias frequency
(speed)
Terminal 1 bias (speed)
Terminal 1 gain frequency
(speed)
Terminal 1 gain (speed)
Terminal 1 bias command
(torque/magnetic flux)
Terminal 1 bias (torque/
magnetic flux)
Terminal 1 gain command
(torque/magnetic flux)
Terminal 1 gain (torque/
magnetic flux)
Terminal 2 frequency setting
bias frequency
Terminal 2 frequency setting
bias
Terminal 2 frequency setting
gain frequency
Terminal 2 frequency setting
gain
Terminal 4 frequency setting
bias frequency
Terminal 4 frequency setting
bias
Terminal 4 frequency setting
gain frequency
Terminal 4 frequency setting
gain
Terminal 4 bias command
(torque/magnetic flux)
Terminal 4 bias (torque/
magnetic flux)
Terminal 4 gain command
(torque/magnetic flux)
Terminal 4 gain (torque/
magnetic flux)
STF terminal function
selection
STR terminal function
selection
RL terminal function selection
RM terminal function selection
RH terminal function selection
RT terminal function selection
AU terminal function selection
JOG terminal function
selection
5. PARAMETERS
5.1 Parameter list
Refer
to page
1
505
501
2
501
517
517
3
517
505
4
505
505
5
505
510
6
510
7
510
510
8
505
505
9
505
505
10
505
505
505
505
510
510
510
510
521
521
521
521
521
521
521
521
207

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents