Mitsubishi Electric FR-A800 Series Instruction Manual page 652

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Pr.
1038
Digital source selection
A930
(1ch)
1039
Digital source selection
A931
(2ch)
1040
Digital source selection
A932
(3ch)
1041
Digital source selection
A933
(4ch)
1042
Digital source selection
A934
(5ch)
1043
Digital source selection
A935
(6ch)
1044
Digital source selection
A936
(7ch)
1045
Digital source selection
A937
(8ch)
1046
Digital trigger channel
A938
1047
Digital trigger operation
A939
selection
 Operation outline
• This function is used to sample the status data (analog monitor and digital monitor) of the inverter, trace the sampling data
when a trigger (trace start condition) occurs, and stores the resulting trace data.
• When the trace function is set enabled, samplings are collected and the inverter goes into the pre-trigger status.
• In the pre-trigger status, samples are collected, and the trigger standby status is entered when sufficient samples for the
number of pre-trigger samples have been collected.
• When a trigger occurs in the trigger standby status, tracing is started and the trace data is stored.
Sampling start
Sampling data
Sampling start
Sampling data
Sampling start
Sampling data
 Tracing procedure
1.
Preparing a USB memory device
Select a USB memory device with ample capacity to store the necessary amount of trace data. When the trace
function is used in the recorder mode, use a USB memory device with at least 1 GB of free space.
Downloaded from
ManualsNet.com
Name
Initial value
1
2
3
4
5
6
7
8
1
0
0%
Data in the period
is discarded.
0%
Data in the period
is discarded.
Trace start
0%
search engine
Setting
range
1 to 255
Select the digital data (I/O signal) for sampling on each channel.
1 to 8
Select the digital channel to be the trigger.
0
Tracing starts when the signal turns ON
1
Tracing starts when the signal turns OFF
If the data is short for the pre-trigger sampling,
the inverter goes into the pre-trigger state.
Pre-trigger sampling number
90%
Once the enough data is collected for trigger sampling,
the inverter goes into the trigger-ready state.
Pre-trigger sampling number
At trigger generation, samples equivalent to the 100%
pre-trigger sampling number are collected and saved.
Description
90%
100%
A trigger occurs
Trace completed
90%
100%
5. PARAMETERS
5.14 (A) Application parameters
1
2
3
4
5
6
7
8
9
10
651

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents