Mitsubishi Electric FR-A800 Series Instruction Manual page 531

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Pr.71
Pr.450
*4
3 (4)
*4
13 (14)
*4
23 (24)
*4
33 (34)
*4
43 (44)
*4
53 (54)
*4
73 (74)
*1*4
333 (334)
*4
8093 (8094)
*4
9093 (9094)
5
15
6
16
9999
(initial
value)
*1
The setting is available for the FR-A820-00630(11K) or lower.
*2
For the FR-A820-03160(55K) or lower, and FR-A840-01800(55K) or lower.
*3
For the FR-A820-03800(75K) or higher, and FR-A840-02160(75K) or higher.
*4
The same operation is performed for the both settings.
NOTE
• Regardless of the Pr.71 (Pr.450) setting, offline auto tuning can be performed according to Pr.96 (Pr.463) Auto tuning
setting/status. (Refer to
 Using two types of motors (RT signal, Pr.450)
• When using two types of motors with one inverter, set Pr.450 Second applied motor.
• The setting value "9999" (initial value) disables the second motor.
• If Pr.450 ≠ 9999, the following parameters will be enabled by turning ON the Second function selection (RT) signal.
530
5. PARAMETERS
5.13 (C) Motor constant parameters
Downloaded from
ManualsNet.com
Motor
Standard motor (such as SF-JR)
Constant-torque motor (SFJRCA,
etc.)
SF-V5RU (other than the 1500 r/
min series)
Mitsubishi Electric standard motor
(SF-JR 4P 1.5kW or lower)
Vector control dedicated motor
SF-V5RU (1500 r/min series)
SF-THY
Mitsubishi Electric high-efficiency
motor SF-HR
Mitsubishi Electric constant-
torque motor SF-HRCA
Mitsubishi Electric high-
performance energy-saving motor
SF-PR
IPM motor MM-CF
IPM motor (other than MM-CF)
SPM motor
Standard motor
Constant-torque motor
Standard motor
Constant-torque motor
No second applied motor
page 532
for offline auto tuning.)
search engine
Motor constant value range when performing
offline auto tuning (increment)
Pr.82 (Pr.455), Pr.859 (Pr.860), Pr.90 (Pr.458),
Pr.91 (Pr.459), Pr.92 (Pr.460), Pr.93 (Pr.461),
Pr.94 (Pr.462), Pr.706 (Pr.738)
• Internal data value 0 to 65534, 9999 (1)
The display increment can be changed in Pr.684.
Pr.82 (Pr.455) and Pr.859 (Pr.860)
• 0 to 500 A, 9999 (0.01 A)
Wye
• 0 to 3600 A, 9999 (0.1 A)
connection
Pr.90 (Pr.458), Pr.91 (Pr.459)
• 0 to 50 Ω, 9999 (0.001 Ω)
• 0 to 400 mΩ, 9999 (0.01 mΩ)
Pr.92 (Pr.460), Pr.93 (Pr.461)
• 0 to 50 Ω, 9999 (0.001 Ω)
• 0 to 3600 mΩ, 9999 (0.1 mΩ)
Delta
Pr.94 (Pr.462)
connection
• 0 to 500 Ω, 9999 (0.01 Ω)
• 0 to 100 Ω, 9999 (0.01 Ω)
Electronic thermal O/L relay
function
Constant-
Standard
torque
*2
*3
*2
*3
*2
*3
*2
*3
PM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents