Monitor item
Input terminal status
Output terminal
status
Option input terminal
*11
status
Option output
*11
terminal status
Option input terminal
status 1 (for
*11
communication)
Option input terminal
status 2 (for
*11
communication)
Option output
terminal status (for
*11
communication)
Motor thermal load
factor
Inverter thermal load
factor
PTC thermistor
resistance
PID measured value
2
*11
Cumulative pulse
Cumulative pulse
*11
overflow times
Cumulative pulse
(control terminal
*11
option)
Cumulative pulse
overflow times
(control terminal
*11
option)
Multi-revolution
*11
counter
450
5. PARAMETERS
5.11 (M) Item and output signal for monitoring
Downloaded from
ManualsNet.com
Increment
Pr.
RS-485
and unit
setting
*12
H0F
*19
55
*13
H10
56
57
*14
H3A
*15
H3B
*16
H3C
0.1%
61
H3D
0.1%
62
H3E
0.01 kΩ
64
H40
0.1%
67
H43
71
H47
72
H48
73
H49
74
H4A
1
75
H4B
search engine
Negative
MODBUS
indication
RTU
*1
(-)
The ON/OFF state of the input terminals on the inverter
*12
is displayed. (Refer to
40215
on the DU.)
The ON/OFF state of the output terminals on the inverter
*13
is displayed. (Refer to
40216
on the DU.)
The ON/OFF state of the input terminals on the digital
input option (FR-A8AX) is displayed on the DU. (Refer to
page 453
The ON/OFF state of the output terminals on the digital
output option (FR-A8AY) or the relay output option (FR-
A8AR) is displayed on the DU. (Refer to
details.)
The ON/OFF state of the input terminals X0 to X15 on the
digital input option (FR-A8AX) is monitored via RS-485
*14
40258
communication or other communication when the
communication option is installed.
The ON/OFF state of the input terminal DY on the digital
input option (FR-A8AX) is monitored via RS-485
*15
40259
communication or other communication when the
communication option is installed.
The ON/OFF state of the output terminals on the digital
output option (FR-A8AY) or the relay output option (FR-
*16
A8AR) is monitored via RS-485 communication or other
40260
communication when the communication option is
installed.
The accumulated heat value of the motor thermal O/L
relay is displayed.
40261
The Motor overload trip (electronic thermal relay
function) (E.THM) occurs at 100%.
The accumulated heat value of the inverter thermal O/L
relay is displayed.
40262
The Inverter overload trip (electronic thermal relay
function) (E.THT) occurs at 100%.
The PTC thermistor resistance is displayed when Pr.561
40264
PTC thermistor protection level ≠ 9999. (The output
voltage is displayed when Pr.561 = 9999.)
The PID measured value is displayed while the PID
control is enabled (Pr.128 ≠ "0"), even if PID control
40267
operating conditions are not satisfied. (Refer to
610.)
The cumulative number of pulses is displayed (for Vector
*20
40271
control compatible plug-in option). (Monitoring range: -
32767 to 32767)
The number of the cumulative pulses carrying overflow
*20
40272
times is displayed (for Vector control compatible plug-in
option).
The cumulative number of pulses is displayed (for the
*20
40273
FR-A8TP). (Monitoring range: -32767 to 32767)
The number of the cumulative pulse overflow times is
*20
40274
displayed (for the FR-A8TP).
The multi-revolution encoder counter is monitored when
40275
the FR-A8APS is installed. (The output voltage is
monitored when the FR-A8APS is not installed.)
Description
page 453
for details on indication
page 453
for details on indication
for details.)
page 453
for
page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents