• Set a positive or negative input (0 to ±5 V or 0 to ±10 V) to terminal 1 to allow the operation of forward/reverse rotation
according to the polarity of the input value.
Reverse
rotation
Reversible
Not reversible
-5
(-10)
Compensation input characteristics
Parameters referred to
Pr.22 Stall prevention operation
Pr.125 Terminal 2 frequency setting gain frequency, Pr.126 Terminal 4 frequency setting gain
Pr.252, Pr.253 Override
Pr.561 PTC thermistor protection
Pr.858 Terminal 4 function assignment, Pr.868 Terminal 1 function
5.12.2 Analog input terminal (terminal 1, 4) function
assignment
The analog input terminal 1 and terminal 4 functions are set and changeable with parameters.
Pr.
868
Terminal 1 function
T010
assignment
858
Terminal 4 function
T040
assignment
• For terminals 1 and 4 used for analog input, the frequency (speed) command, magnetic flux command, torque command,
and other similar commands are usable. The functions available are different depending on the control method and control
mode as shown in the following table. (For details on the control methods, refer to
• Functions of terminal 1 under different control modes
Pr.868
Advanced magnetic flux vector
setting
0 (initial
Auxiliary frequency setting
value)
1
2
3
4
Stall prevention operation level input
5
6
9999
• Functions of terminal 4 under different control modes
Pr.858
Advanced magnetic flux vector
setting
0 (initial
Frequency command (AU signal-
value)
ON)
1
Stall prevention operation level
4
input
9999
500
5. PARAMETERS
5.12 (T) Multi-function input terminal parameters
Downloaded from
ManualsNet.com
Set frequency
Forward
(Hz)
rotation
60
+5
(+10)
0
Terminal 1 input (V)
when STF is ON
levelpage 431
bias/gainpage 501
levelpage 415
Name
Initial value
0
0
V/F control,
control
Auxiliary speed setting
Magnetic flux command
Regenerative torque limit
(Pr.810 = "1")
Torque limit (Pr.810 = "1")
Torque bias input (Pr.840 =
"1, 2, or 3")
V/F control,
control
Speed command (AU signal-
ON)
Magnetic flux command
Torque limit (Pr.810 = "1")
search engine
assignmentpage 500
Setting range
0 to 6, 9999
Select the terminal 1 function.
0, 1, 4, 9999
Select the terminal 4 function.
Real sensorless vector control, Vector control, PM sensorless vector control
Speed control
Auxiliary speed limit
*1
Magnetic flux command
Torque command (Pr.804
= "0")
Torque command (Pr.804
= "0")
Forward/reverse rotation
speed limit (Pr.807 = "2")
Real sensorless vector control, Vector control, PM sensorless vector control
Speed control
Speed limit (AU signal-ON) —
*1*2
Magnetic flux command
*3
frequencypage 505
Description
page
221.)
Torque control
Position control
*1
Magnetic flux command
Regenerative torque limit
(Pr.810 = "1")
Torque limit (Pr.810 = "1")
Torque control
Position control
*1*2
Magnetic flux command
Torque limit (Pr.810 = "1")
*1
*1*2
*3

Hide quick links: