 Rated frequency (Pr.999 = "20" (50 Hz) or "21" (60 Hz))
Pr.
3
Base frequency
4
Multi-speed setting (high speed)
Acceleration/deceleration reference
20
frequency
37
Speed display
55
Frequency monitoring reference
Stall prevention operation reduction
66
starting frequency
116
Third output frequency detection
Terminal 2 frequency setting gain
125 (903)
frequency
Terminal 4 frequency setting gain
126 (905)
frequency
263
Subtraction starting frequency
Power failure deceleration time
266
switchover frequency
386
Frequency for maximum input pulse 60 Hz
505
Speed setting reference
Forward rotation speed limit/speed
808
limit
C14 (918)
Terminal 1 gain frequency (speed)
5.7.17 Extended parameter display and user group
function
This function restricts the parameters that are read by the operation panel and parameter unit.
Pr.
160
User group read
E440
selection
172
User group registered
E441
display/batch clear
173
User group registration
E442
174
User group clear
E443
*1
The read value is always "9999".
 Display of simple mode parameters and extended parameters (Pr.160)
• When Pr.160 = "9999", only the simple mode parameters are displayed on the operation panel (FR-DU08) and parameter
unit (FR-PU07). (For the simple mode parameters, refer to the parameter list on
• With the initial value (Pr.160 = "0", simple mode parameters and extended parameters can be displayed.
354
5. PARAMETERS
5.7 (E) Environment setting parameters
Downloaded from
ManualsNet.com
Name
60 Hz
60 Hz
60 Hz
0
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
Name
Initial value
0
0
*1
9999
*1
9999
search engine
Initial value
FM type
CA type
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
Setting range
9999
Only simple mode parameters are displayed.
0
Displays simple mode and extended parameters.
1
Only parameters registered in user groups are displayed.
Displays the number of parameters that are registered in the
(0 to 16)
user groups. (Read-only)
9999
Batch clear of user group registrations
0 to 1999, 9999
Sets the parameter number to register for the user group.
0 to 1999, 9999
Sets the parameter number to clear from the user group.
Pr.999 = "21"
Pr.999 = "20"
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
0
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
Description
page
166.)
Refer to
page
707
411
367
444
457
431
431
505
642
406
444
287
505