Pr.
52
Operation panel main
M100
monitor selection
774
Operation panel monitor
M101
selection 1
775
Operation panel monitor
M102
selection 2
776
Operation panel monitor
M103
selection 3
Operation panel setting
992
dial push monitor
M104
selection
54
FM/CA terminal function
M300
selection
158
AM terminal function
M301
selection
Cumulative power
891
monitor digit shifted
M023
times
892
Load factor
M200
Energy saving monitor
893
reference (motor
M201
capacity)
Control selection during
894
commercial power-
M202
supply operation
895
Power saving rate
M203
reference value
896
Power unit cost
M204
897
Power saving monitor
M205
average time
898
Power saving cumulative
M206
monitor clear
899
Operation time rate
M207
(estimated value)
*1
For the FR-A820-03160(55K) or lower, and FR-A840-01800(55K) or lower.
*2
For the FR-A820-03800(75K) or higher, and FR-A840-02160(75K) or higher.
468
5. PARAMETERS
5.11 (M) Item and output signal for monitoring
Downloaded from
ManualsNet.com
Name
Initial value
0 (output
frequency)
9999
0 (set frequency)
1 (output
frequency)
9999
100%
Inverter rated
capacity
0
9999
9999
9999
9999
9999
search engine
Setting range
Refer to
page
50: Energy saving effect monitoring,
446.
51: Cumulative energy saving monitoring
Refer to
page
50: Energy saving effect monitoring
457.
Set the number of times to move the digit of cumulative power
0 to 4
monitored value. The readout peaks out at the upper limit of
readout.
The function of moving the decimal point is not available. The
9999
readout is reset to 0 when it exceeds the upper limit.
Set the load factor for the commercial power supply operation.
The setting is used for calculation of the estimated power
30 to 150%
consumption during commercial power supply operation by
being multiplied by the power consumption rate
Set the motor capacity (pump capacity). Setting this parameter
*1
0.1 to 55 kW
is required for calculating the rate of saved power, the rate of
*2
0 to 3600 kW
average energy saving, and the commercial power.
0
Discharge damper control (fan)
1
Inlet damper control (fan)
2
Valve control (pump)
3
Commercial power supply drive (fixed value)
0
Consider the commercial power as 100%.
1
Consider the power set in Pr.893 as 100%
9999
No function
Set the power unit cost. Setting this parameter is required for
0 to 500
displaying the energy cost savings in the energy saving
monitoring.
9999
No function
0
The time period for averaging is 30 minutes.
1 to 1000 h
Set the number of hours for averaging.
9999
No function
0
Clear the cumulative monitor value
1
Hold the cumulative monitor value
10
Continue accumulation (upper limit communication data is 9999)
Continue accumulation (upper limit communication data is
9999
65535)
Setting this parameter is required for calculating the annual
0 to 100%
energy saving. Set an annual operating rate (considering a 24-
hours-a-day and 365-days-a-year operation as 100%).
9999
No function
Description
(page
472).