Free Parameter; Setting Multiple Parameters By Batch - Mitsubishi Electric FR-A800 Series Instruction Manual

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

*3
Inputting a password is possible but the locked-up password cannot be unlocked or reset even with the valid password.
*4
Parameter clear can be performed only via a communication option.
NOTE
• When "4, 5, 104, or 105" is set in Pr.296 and a password is set, Pr.15 Jog frequency is not listed on the parameter unit (FR-
PU07).
• When a password has been set and parameters are locked, Parameter copy cannot be performed using the operation panel,
parameter unit, or a USB memory device.
Parameters referred to
Pr.77 Parameter write
Pr.160 User group read
Pr.550 NET mode operation command source
Pr.551 PU mode operation command source

5.7.15 Free parameter

Any number within the setting range of 0 to 9999 can be input.
For example, these numbers can be used:
• As a unit number when multiple units are used.
• As a pattern number for each operation application when multiple units are used.
• As the year and month of introduction or inspection.
Pr.
888
Free parameter 1
E420
889
Free parameter 2
E421
NOTE
• Pr.888 and Pr.889 do not influence the operation of the inverter.

5.7.16 Setting multiple parameters by batch

The setting of particular parameters is changed by batch, such as communication parameters for connection with the Mitsubishi
Electric human machine interface (GOT), the parameters for the rated frequency (50/60 Hz) setting, or the parameters for
acceleration/deceleration time increment.
Multiple parameters are changed automatically. Users do not have to consider each parameter number (automatic parameter
setting).
Pr.
999
Automatic parameter
E431
setting
*1
The read value is always "9999".
350
5. PARAMETERS
5.7 (E) Environment setting parameters
Downloaded from
ManualsNet.com
selectionpage 345
selectionpage 354
selectionpage 400
selectionpage 400
Name
Initial value
9999
9999
Name
Initial value
*1
9999
search engine
Setting range
0 to 9999
Any value can be input.
The settings are retained even if the inverter power is turned
OFF.
0 to 9999
Setting
range
1
Standard PID display setting
2
Extended PID display setting
10
GOT initial setting (PU connector)
11
GOT initial setting (RS-485 terminal)
12
GOT initial setting (PU connector)
13
GOT initial setting (RS-485 terminal)
20
50 Hz rated frequency
21
60 Hz rated frequency
9999
No action
Description
Description
"Controller Type" in GOT:
FREQROL 500/700/800,
SENSORLESS SERVO
"Controller Type" in GOT:
FREQROL 800 (Automatic
Negotiation)