 Analog source (monitor item) selection
• Select the analog sources (monitor items) to be set to Pr.1027 to Pr.1034 from the following table.
Setting
Monitor item
value
1
Output frequency/speed
2
Output current
3
Output voltage
Frequency setting value/motor
5
speed setting
6
Running speed
7
Motor torque
8
Converter output voltage
*5
Regenerative brake duty
9
Electronic thermal O/L relay load
10
factor
11
Output current peak value
Converter output voltage peak
12
value
13
Input power
14
Output power
17
Load meter
18
Motor excitation current
19
Position pulse
20
Cumulative energization time
22
Orientation status
23
Actual operation time
24
Motor load factor
32
Torque command
33
Torque current command
34
Motor output
35
Feedback pulse
Torque monitor (power driving/
36
regenerative driving polarity
switching)
SSCNET III communication
39
*7
status
40
PLC function user monitor 1
41
PLC function user monitor 2
42
PLC function user monitor 3
46
Motor temperature
52
PID set point
53
PID measured value
54
PID deviation
61
Motor thermal load factor
62
Inverter thermal load factor
64
PTC thermistor resistance
67
PID measured value 2
71
Cumulative pulse
654
5. PARAMETERS
5.14 (A) Application parameters
Downloaded from
ManualsNet.com
Minus (-)
*1
*2
display
search engine
Trigger
level
Setting
*3
criterion
Cumulative pulse overflow times
*4
74
(control terminal option)
*4
75
Multi-revolution counter
*4
87
Remote output value 1
*4
88
Remote output value 2
*4
89
Remote output value 3
*4
90
Remote output value 4
*4
91
PID manipulated amount
Second PID set point/deviation
*4
92
input selection
*4
93
Second PID measured value
*4
94
Second PID deviation
*4
95
Second PID measured value 2
*4
96
Second PID manipulated amount ○
*4
97
Dancer main set speed
*4
98
Control circuit temperature
*4
201
*Output frequency
65535
202
*U-phase output current
65535
203
*V-phase output current
65535
204
*W-phase output current
65535
205
Converter output voltage
*4
206
*Output current (all three phases)
*4
207
*Excitation current (A)
*4
208
*Torque current (A)
*4
209
Terminal 2
65535
210
Terminal 4
*4
211
Terminal 1
65535
212
*Excitation current (%)
*4
213
*Torque current (%)
*4
222
Position command
*4
223
Position command (upper digits)
*4
224
Current position
*4
225
Current position (upper digits)
*4
226
Droop pulse
*4
227
Droop pulse (upper digits)
*4
230
*Output frequency (signed)
*4
231
*Motor speed (with sign)
Pr.561
232
*Speed command (with sign)
*4
235
*Torque command
*4
236
*Motor torque
Minus (-)
*1
Monitor item
display
Trigger
level
*2
*3
criterion
*4
65535
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
Pr.84
ND rated
current
ND rated
current
ND rated
current
400 V/800 V
ND rated
current
ND rated
current
ND rated
current
100%
100%
100%
100%
100%
65535
65535
65535
65535
65535
65535
Pr.84
*6
*6
100%
100%