 Remote register (from the master module to the inverter)
Device No.
RWw0
*5
RWw2
RWw4
RWw5
RWw6
RWw10,
RWw12,
RWw14,
RWw16,
RWw18,
RWw1A
RWw11,
RWw13,
RWw15,
RWw17,
RWw19,
RWw1B
RWw21
RWw26
RWw27
RWw28
RWw29
RWw2A
RWw2B
RWw2C
RWw2D
RWw2E
RWw2F
*1
The rotation speed command or the machine speed command is selected according to the combination of Pr.37, Pr.144, and Pr.811. (Refer to
page
*2
When Pr.541 Frequency command sign selection = "1", the set frequency is a signed value. When the setting value is negative, the command
is the inverse from the start command. Setting range: -327.68 Hz to 327.67 Hz (-327.68 to 327.67), 0.01 Hz increments. (Refer to
*3
When Pr.128 = "50, 51, 60, or 61", the register is valid. If the data outside the range is set, the previous setting is retained. (Refer to
*4
Write data is in hexadecimal, and only two digits are valid. (The upper two digits are ignored.)
*5
The value in RWw2 is used as the torque limit value during speed control or position control, and as the torque command value during torque
control. (Torque control cannot be performed with a PM motor.) To use the value as the torque limit value, set Pr.810 = "2".
Downloaded from
ManualsNet.com
Signal
*1*2
Set frequency
Torque command value
Torque limit value
*3
PID set point
*3
PID measured value
*3
PID deviation
Link parameter extended
setting / instruction code
Write data
*4
Fault history No.
*4
Monitor code 1
*4
Monitor code 2
*4
Monitor code 3
*4
Monitor code 4
*4
Monitor code 5
*4
Monitor code 6
*4
Monitor code 7
*4
Monitor code 8
*4
Monitor code 9
*4
Monitor code 10
444.)
search engine
• Specify the set frequency or rotations per minute (machine speed). At this time, whether
to write to RAM or EEPROM is decided with the RY21 and RY22 settings. After setting
the set frequency in this register, set "1" in RY21 or RY22 to write the frequency. After
writing of frequency is completed, "1" is set in RX21 or RX22 in response to the input
command.
• The setting range is 0 to 590.00 Hz (0.01 Hz increments). Write "59000" when setting
590.00 Hz.
Specify the torque command value / torque limit value. Set Pr.804 Torque command
source selection = "1, 3, 5, or 6" to activate this signal under Real sensorless vector
control, Vector control, and PM sensorless vector control. The value is written to the
inverter either by RY23 or RY24. Pr.805 Torque command value (RAM) and Pr.806
Torque command value (RAM, EEPROM) are updated as well. The setting range and
the setting increment depend on the Pr.804 setting. (Refer to
Set the PID action set point.
Setting range: 0 to 100.00%
Set the PID measured value.
Setting range: 0 to 100.00%
Set the PID deviation.
Setting range: -100.00 to 100.00%
Set an instruction code (refer to
switching, parameter read/write, error reference, and error clear in the lower eight bits. The
instructions are executed in the following order by setting "1" in RY25 after completing the
register setting: RWw10, 12, 14, 16, 18, then 1A. After completing the execution up to
RWw1A, "1" is set in RX25. Set HFFFF to disable an instruction by RWw10 to 1A.
Set the link parameter extended setting in the upper 8 bits.
Example) When reading Pr.160, instruction code is H0200.
Set the data specified by the instruction code of RWw10, 12, 14, 16, 18 and 1A (when
required).
RWw10 and 11, 12 and 13, 14 and 15, 16 and 17, 18 and 19, and 1A and 1B correspond
each other. Set "1" in RY25 after setting the instruction codes (RWw10, 12, 14, 16, 18 and
1A) and the corresponding register.
Set "0" when the write data is not required.
Set the individual fault number of the fault history that you want to read. Fault records can
be read back to the eighth latest fault.
Last two digits: H00 (latest fault) to H07 (eighth latest fault)
Set H08 to HFF to make the fault history No. to "0".
Set the monitor code to be monitored. By setting "1" in RY20 after setting, the specified
monitor data is stored in RWr26 to RWr2F.
If a monitor code out of the setting range is set, no item is monitored (the monitor value is
fixed to 0).
The monitor codes are the same as those of the RS-485 communication dedicated
monitor. (Refer to
page
446.)
When the remote registers RWw26 to 2F are used for monitoring, H01 (output frequency)
and H05 (set frequency) always indicate the frequency regardless of the settings of Pr.37,
Pr.144, and Pr.811.
Description
page
• Input a value 100 times greater than the value to be
set. For example, enter "10000" when setting
100.00%.
• Refer to
page 601
for details on PID control.
page
760) for an operation such as operation mode