Mitsubishi Electric FR-A800 Series Instruction Manual page 450

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Monitor item
Current position
(lower digits)
Current position
(upper digits)
Droop pulse (lower
digits)
Droop pulse (upper
digits)
Torque command
Torque current
command
Motor output
Feedback pulse
Torque (positive
polarity for driving
torque/negative
polarity for
regenerative braking
torque)
Trace status
SSCNET III
communication
*11
status
PLC function user
monitor 1
PLC function user
monitor 2
PLC function user
monitor 3
Station number (RS-
485 terminals)
Station number (PU)
Station number (CC-
Link)
Motor temperature
Power saving effect
Cumulative energy
saving
PID set point
PID measured value
PID deviation
Downloaded from
ManualsNet.com
Increment
Pr.
and unit
setting
1
28
1
29
1
30
1
31
0.1%
32
0.1%
33
*6
34
0.01/0.1 kW
*11
35
0.1%
36
1
38
1
39
40
Increment set
41
in the register
SD1215
42
1
43
1
44
1
45
*11
1°C
46
Increment
50
and unit vary
depending on
51
the parameter
settings.
0.1%
52
0.1%
53
0.1%
54
search engine
Negative
MODBUS
RS-485
indication
RTU
*1
(-)
H1C
40228
H1D
40229
H1E
40230
H1F
40231
H20
40232
H21
40233
H22
40234
H23
40235
H24
40236
H26
40238
H27
40239
H28
40240
H29
40241
H2A
40242
H2B
40243
H2C
40244
H2D
40245
H2E
40246
H32
40250
H33
40251
H34
40252
H35
40253
H36
40254
Description
The converted number of the position feedback pulse
into the number of pulses before the electronic gear is set
*10
is displayed.
The droop pulse before the electronic gear is set is
*10
displayed.
The torque command value adjusted with Vector control
is displayed.
The command value of the current for torque is
displayed.
The output of a machine connected to the motor shaft is
displayed. It is determined by multiplying the present
output torque with the present motor speed.
The number of pulses fed back from the encoder in one
cycle of the sampling is displayed (kept displayed during
a stop). (The output voltage is displayed when a Vector
control option is not installed.)
The sampling time period varies depending on the
Pr.369 Number of encoder pulses setting.
1050 or less: 1 s,
1051 to 2100: 0.5 s,
2101 to 4096: 0.25 s
The value equal to the motor torque is displayed.
A positive value for driving torque or a negative value for
regenerative braking torque is displayed.
The trace status is displayed. (Refer to
The SSCNET III communication status between the
inverter and the controller is displayed.
The output voltage is displayed when the FR-A8NS is not
installed.
The user-designated monitor item is displayed using the
PLC function.
Each value of the following special registers is displayed.
SD1216: displayed with the setting value "40",
SD1217: displayed with the setting value "41",
SD1218: displayed with the setting value "42"
(Refer to the PLC Function Programming Manual.)
The station number of the inverter enabling
communication via the RS-485 terminals is displayed.
The station number of the inverter enabling
communication via the PU connector is displayed.
The station number of the inverter enabling CC-Link
communication is displayed. ("0" is displayed when the
FR-A8NS is not installed.)
The temperature of the Vector control dedicated motor
with thermistor (SF-V5RU[]T/A) is displayed (for the FR-
A8AZ).
The energy saving effect monitoring is enabled. The item
to monitor is selectable from among the saved power, the
average energy saving, and the energy cost savings.
Some of them can be displayed as a percentage
according to the parameter settings. (Refer to
The set point, measured value, and deviation during PID
control operation is displayed. (Refer to
5.11 (M) Item and output signal for monitoring
1
2
3
4
5
6
7
8
page
649.)
9
10
page
467.)
page
610.)
449
5. PARAMETERS