Conditions
Command
interface
External
control
circuit
terminal
○: Valid, ×: Invalid, Δ: Partially valid
*1
RS-485 communication via PU connector
*2
Follows the Pr.338 Communication operation command source and Pr.339 Communication speed command source settings. (Refer to
page
*3
At occurrence of RS-485 communication error, the inverter cannot be reset from the computer.
*4
Only PU stop is enabled. "PS" is displayed on the operation panel during PU stop. The operation follows the Pr.75 Reset selection/
disconnected PU detection/PU stop selection setting. (Refer to
*5
Writing of some parameters may be disabled by the Pr.77 Parameter write selection setting and the operating condition. (Refer to
*6
Some parameters are write-enabled independently of the operation mode and command source presence/absence. Writing is also enabled when
Pr.77 = "2"
(refer to
*7
When Pr.550 NET mode operation command source selection = "1" (RS-485 terminals enabled), or Pr.550 NET mode operation command
source selection = "9999" with no communication option connected.
*8
When Pr.550 NET mode operation command source selection = "0" (communication option enabled), or Pr.550 NET mode operation
command source selection = "9999" with communication option connected.
 Operation when a communication error occurs
Fault type
Inverter fault
PU connector
disconnection
Communication error
at PU connector
Communication error
at RS-485 terminals
Communication error
at USB connector
Communication error
at communication
option
*1
Selectable with Pr.75 Reset selection/disconnected PU detection/PU stop selection.
*2
Selectable with Pr.122 PU communication check time interval, Pr.336 RS-485 communication check time interval, and Pr.548 USB
communication check time interval.
*3
The operation depends on the communication option setting.
*4
In the PU JOG operation mode, operation always stops when the PU is disconnected. The operation at a PU disconnection fault (E.PUE)
occurrence is as set in Pr.75 Reset selection/disconnected PU detection/PU stop selection.
*5
When Pr.550 NET mode operation command source selection = "1" (RS-485 terminals enabled), or Pr.550 NET mode operation command
source selection = "9999" with no communication option connected.
*6
When Pr.550 NET mode operation command source selection = "0" (communication option enabled), or Pr.550 NET mode operation
command source selection = "9999" with communication option connected.
Downloaded from
ManualsNet.com
(Pr.551
Item
setting)
Inverter reset
Operation command
(start, stop)
Frequency setting
400.)
page
345). Parameter clear is disabled.
Conditions (Pr.551
setting)
PU operation
Stop
2 (PU connector),
9999 (automatic
Stop/continued
recognition)
Other than 2
Stop/continued
Stop/
2 (PU connector)
continued
Other than 2
Continued
Stop/
1 (RS-485 terminals)
continued
Other than 1
Continued
3 (USB connector),
Stop/
9999 (automatic
continued
recognition)
Other than 3
Continued
Continued
search engine
Controllability in each operation mode
Combined
PU
External
operation
operation
operation
mode 1
(Pr.79 = "3")
×
×
×
page
336.)
Operation in each operation mode at error occurrences
Combined
External
operation
operation
mode 1
(Pr.79 = "3")
*1*4
*1
Continued
*2
Continued
*2
Continued
*2
Combined
NET operation
operation
(via RS-485
mode 2
terminals)
(Pr.79 = "4")
*2
×
×
*2
×
Combined
NET operation
operation
(via RS-485
mode 2
terminals)
(Pr.79 = "4")
Stop/
Continued
*2
continued
Stop/
Continued
*2
continued
Stop/
continued
5.9 (D) Operation command and frequency command
1
NET operation
*8
(via option)
*7
2
3
4
5
page
345.)
6
7
8
NET
operation (via
*5
*6
option)
9
10
Continued
*2
Stop/
*3
continued
403
5. PARAMETERS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents