Mitsubishi Electric FR-A800 Series Instruction Manual page 324

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Clearing condition
Servo-OFF (LX-OFF)
(output shutoff)
Clear signal input
Home position return
completed
When position control is
switched to other control
mode
Clear signal input
(under the control mode
other than position
control)
○: cleared, ×: not cleared
*1
The droop pulses are not cleared.
*2
The CLR/CLRN signal is input when a value other than "1" is set in Pr.419, and the signal is input through terminal CR of the FR-A8AL when
Pr.419 = "1".
*3
Pulses are cleared when a clear signal is input. (The home position information is not retained.)
*4
Pulses are cleared only when the home position return is completed. Once the pulses are cleared, they are not cleared even if the LX signal is
turned ON.
*5
The data is cleared when absolute position control is disabled.
*6
The home position return is not available.
*7
The following shows the example of the clearing the value of the current position 2 monitor under the control mode other than the position control
mode.
Monitoring of
current position 2
NOTE
• The monitor value of the current position 2 is not cleared when switching between the first and second motors.
• For details on the special register for the PLC function, refer to the PLC Function Programming Manual.
 Pulse monitoring on the operation panel (FR-DU08)
• The position command, current position and the status of droop pulses can be displayed on the operation panel.
• If displayed data has signs, minus signs appear for both upper and lower digits.
• If -99999999 or 99999999 is exceeded on the pulse monitor, the monitor value is reset to 0.
Display data
-10000
-100
NOTE
• The pulse count starts at servo on.
Downloaded from
ManualsNet.com
0
10
×
×
×
*2
*3
×
×
×
×
×
MC
ON
OFF
STF
ON
Monitor value
updated
0
Position
Other than position
control
control (speed)
Not cleared to 0 at
the control switchover
Monitor display without signs
Lower monitor
Upper monitor
Lower monitor
Upper monitor
search engine
Current position 2
Pr.419 setting
100
110
1, 2
1110
×
×
×
*3
*5
×
*6
×
×
×
ON
STF
CLR
Monitoring of
current position 2
0
Position
control
Not cleared to 0 at
the control switchover
Monitor display with signs
5.5 Position control under vector control and PM sensorless vector control
200
210
300
×
×
×
×
×
*7
*7
*7
×
×
×
*7
*7
*7
ON
OFF
OFF
Cleared to 0
by turning ON
of the CLR signal
Other than position control (speed)
1
310
1310
×
×
2
*5
×
3
*7
*7
×
×
4
*7
*7
5
6
7
ON
8
9
10
323
5. PARAMETERS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents