Pr.
463
Second motor auto
C210
tuning setting/status
458
Second motor
C220
constant (R1)
Second motor
460
constant (L1) / d-axis
C222
inductance (Ld)
Second motor
461
constant (L2) / q-axis
C223
inductance (Lq)
Second motor torque
860
current/Rated PM
C226
motor current
738
Second motor induced
C230
voltage constant (phi f)
Second motor induced
1413
voltage constant (phi f)
C235
exponent
739
Second motor Ld
C231
decay ratio
740
Second motor Lq
C232
decay ratio
Second starting
741
resistance tuning
C282
compensation
Second motor
742
magnetic pole
C285
detection pulse width
Second motor
746
protection current
C233
level
*1
For the FR-A820-00077(0.75K) or lower and FR-A840-00038(0.75K) or lower, it is set to 85% of the inverter rated current.
*2
For the FR-A820-03160(55K) or lower, and FR-A840-01800(55K) or lower.
*3
For the FR-A820-03800(75K) or higher, and FR-A840-02160(75K) or higher.
*4
The initial value differs according to the voltage class (200 V / 400 V).
*5
The setting range and unit change according to the Pr.71 (Pr.450) setting.
• The settings are valid under PM sensorless vector control.
• The offline auto tuning enables the operation with SPM motors and IPM motors other than MM-CF. (When a PM motor other
than the IPM motor MM-CF is used, always perform offline auto tuning.)
• Tuning is enabled even when a load is connected to the motor.
• Reading/writing of the motor constants tuned by offline auto tuning are enabled. The offline auto tuning data (motor constants)
can be copied to another inverter using the operation panel.
• The offline auto tuning status can be monitored on the operation panel or the parameter unit.
 Before performing offline auto tuning
Check the following points before performing offline auto tuning:
• Check that PM sensorless vector control is selected.
• Check that a motor is connected. (Check that the motor is not rotated by an external force during tuning.)
Downloaded from
ManualsNet.com
Initial
Name
value
0, 101
1
0
11
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
0 to 500 mH, 9999
9999
0 to 50 mH, 9999
0 to 500 mH, 9999
9999
0 to 50 mH, 9999
0 to 500 A, 9999
9999
0 to 3600 A, 9999
0 to 5000 mV (rad/s)
9999
9999
0 to 2
9999
9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
0 to 6000 μs, 10000 to
9999
16000 μs, 9999
100 to 500%
9999
9999
search engine
Setting range
No auto tuning for the second motor.
Offline auto tuning is performed without rotating the motor
(motor other than IPM motor MM-CF).
Offline auto tuning is performed without rotating the motor (for
IPM motor MM-CF).
*2*5
*3*5
*2*5
Tuning data of the second motor.
(The value measured by offline auto tuning is automatically
*3*5
set.)
*2*5
9999: The MM-CF constant is used when the IPM motor MM-
CF is selected, and the inverter internal data is used when a PM
*3*5
motor other than MM-CF is selected.
*2*5
*3*5
*5
Set this parameter according to the PM motor specifications.
The value calculated from the parameter setting for motor
constant is used.
Set the exponent n when the induced voltage constant phi f
(Pr.738) is multiplied by 10
No exponent setting
Tuning data of the second motor.
(The value measured by offline auto tuning is automatically
set.)
9999: The MM-CF constant is used when the IPM motor MM-
CF is selected, and the inverter internal data is used when a PM
motor other than MM-CF is selected.
Set the maximum current (OCT) level of the second motor.
The MM-CF constant is used when the IPM motor MM-CF is
selected, and 200% when a PM motor other than MM-CF is
selected.
Description
n
.
5. PARAMETERS
5.13 (C) Motor constant parameters
1
2
3
4
5
6
7
8
9
10
553