Signal
Setting
name
6
CS
7
OH
8
REX
9
X9
10
X10
11
X11
12
X12
13
X13
14
X14
15
BRI
16
X16
17
X17
18
X18
19
X19
20
X20
22
X22
23
LX
24
MRS
STP
25
(STOP)
26
MC
27
TL
28
X28
32
X32
37
X37
42
X42
43
X43
44
X44
45
BRI2
46
TRG
47
TRC
48
X48
50
SQ
51
X51
52
X52
53
X53
57
JOGF
58
JOGR
59
CLRN
60
STF
61
STR
62
RES
64
X64
65
X65
522
5. PARAMETERS
5.12 (T) Multi-function input terminal parameters
Downloaded from
ManualsNet.com
Selection of automatic restart after instantaneous power failure /
flying start
Electronic bypass function
External thermal relay input
15-speed selection (Combination with multi-speeds of RL, RM, and
RH)
Third function selection
Inverter run enable (FR-HC2/FR-XC/FR-CV/FR-CC2 connection)
FR-HC2/FR-CC2 connection, instantaneous power failure
detection
PU operation external interlock
External DC injection brake operation start
PID control valid
Brake opening completion
PU/External operation switchover (External operation with X16-ON) Pr.79, Pr.340
Load pattern selection forward/reverse rotation boost (For
constant-torque with X17-ON)
V/F switchover (V/F control with X18-ON)
Load torque high-speed frequency
S-pattern acceleration/deceleration C switchover
Orientation command (for Vector control compatible options)
*5
Pre-excitation/servo ON
Output stop
Electronic bypass function
Start self-holding selection
Control mode switchover
Torque limit selection
Start-time tuning start external input
External fault input
Traverse function selection
Torque bias selection 1
Torque bias selection 2
P/PI control switchover (P control with X44-ON)
Second brake sequence open completion
Trace trigger input
Trace sampling start/end
Power failure stop external
Sequence start
Fault clear
Cumulative pulse monitor clear (for Vector control compatible plug-
in options)
Cumulative pulse monitor clear (control terminal option) (for FR-
A8TP)
JOG forward rotation command
JOG reverse rotation command
NET position pulse clear
Forward rotation command (assignable to the STF terminal
(Pr.178) only)
Reverse rotation command (assignable to the STR terminal
(Pr.179) only)
Inverter reset
PID forward/reverse action switchover
PU/NET operation switchover (PU operation with X65-ON)
search engine
Function
*3
Related parameter
Pr.57, Pr.58, Pr.162 to
Pr.165, Pr.299, Pr.611
Pr.57, Pr.58, Pr.135 to
Pr.139, Pr.159
Pr.9
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.110 to Pr.116
Pr.30, Pr.70, Pr.599
Pr.30, Pr.70
Pr.79
Pr.10 to Pr.12
Pr.127 to Pr.134, Pr.575 to
Pr.577
Pr.278 to Pr.285
Pr.14
Pr.80, Pr.81, Pr.800
Pr.270 to Pr.274
Pr.380 to Pr.383
*4*6
Pr.350 to Pr.369
Pr.850
Pr.17
Pr.57, Pr.58, Pr.135 to
Pr.139, Pr.159
Pr.250
Pr.800
Pr.815
Pr.95
Pr.592 to Pr.597
Pr.840 to Pr.845
Pr.840 to Pr.845
Pr.820, Pr.821, Pr.830,
Pr.831
Pr.641 to Pr.648
Pr.1020 to Pr.1047
Pr.1020 to Pr.1047
Pr.261 to Pr.266, Pr.294,
Pr.668
Pr.414
Pr.414
Pr.635
Pr.15, Pr.16
Pr.15, Pr.16
Pr.291, Pr.419 to Pr.430,
Pr.464
Pr.250
Pr.250
Pr.75
Pr.127 to Pr.134
Pr.79, Pr.340
Refer to
page
628,
635
563
415
411
525
724
724
389
715
601
572
389
708
221
580
372
585
715
524
563
722
221
245
558
525
582
265
265
254
572
649
649
642
646
646
321
410
410
320
722
722
336
601
389

Hide quick links: