5.9
To select the operation mode
To start up the inverter in Network operation
mode at power-ON
To select the command source during
communication operation
To prevent the motor from rotating
reversely
To change the setting resolution of speed
To change the setting resolution of the
torque limit
To set the frequency using pulse train input Pulse train input
To perform JOG (inching) operation
To control the frequency with combinations
of terminals
To select the torque command method
during torque control
5.9.1
Select the operation mode of the inverter.
The mode can be changed among operations using external signals (External operation), operation by the operation panel or
the parameter unit (PU operation), combined operation of PU operation and External operation (External/PU combined
operation), and Network operation (when RS-485 terminals or a communication option is used).
Pr.
79

Operation mode selection 0

D000
The following table lists valid and invalid commands in each operation mode.
Downloaded from
ManualsNet.com

(D) Operation command and frequency command

Purpose
Operation mode selection P.D000
Communication startup
mode selection
Operation and speed
command sources during
communication operation,
command source
selection
Reverse rotation
prevention selection
Set resolution switchover P.D030
Set resolution switchover P.D030
JOG operation
Multi-speed operation
Torque command source
selection
Operation mode selection
Name
Initial value
search engine
Parameter to set
P.D000, P.D001
P.D010 to P.D013
P.D020
P.D100, P.D101,
P.D110, P.D111
P.D200, P.F002
P.D300 to P.D315
P.D120, P.D121,
P.D400 to P.D402
Setting range
0 to 4, 6, 7
Selects the operation mode.
5.9 (D) Operation command and frequency command
Refer to
page
Pr.79
389
Pr.79, Pr.340
398
Pr.338, Pr.339, Pr.550,
400
Pr.551
Pr.78
406
Pr.811
444
Pr.811
444
Pr.291, Pr.384 to
406
Pr.386
Pr.15, Pr.16
410
Pr.28, Pr.4 to Pr.6,
Pr.24 to Pr.27, Pr.232
411
to Pr.239
Pr.432, Pr.433, Pr.804
283
to Pr.806
Description
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
389

Hide quick links:

Advertisement