Mitsubishi Electric FR-A800 Series Instruction Manual page 91

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

• When using an encoder cable (FR-JCBL, FR-V5CBL, etc.) dedicated to the conventional motor, the cables need to be
treated as the terminal block of the FR-A8AP is an insertion type. Cut the crimp terminal of the encoder cable and strip its
sheath to make its cable wires loose. Also, treat the shielding wires of the shielded twisted pair cable to ensure that they
do not contact conductive areas.
Wire the stripped cable after twisting it to prevent it from becoming loose. In addition, do not solder it.
NOTE
• Information on crimp terminals
Commercially available products (as of October 2020)
Phoenix Contact Co., Ltd.
Terminal screw
M2
NICHIFU Co., Ltd.
Terminal screw
M2
• When using a blade terminal (without insulation sleeve), take caution that the twisted wires do not come out.
• Connection terminal compatibility table
Motor
Encoder cable
FR-A8AP terminal
90
2. INSTALLATION AND WIRING
2.8 Connection to a motor with encoder (Vector control)
Downloaded from
ManualsNet.com
Cable stripping size
5 mm
Wire gauge
2
size
(mm
)
0.3
AI 0,34-6TQ
0.5
AI 0,5-6WH
Wire gauge
2
size
(mm
)
0.3 to 0.75
SF-V5RU, SF-THY
FR-V7CBL
PA1
PA
PA2
Do not connect anything to this.
PB1
PB
PB2
Do not connect anything to this.
PZ1
PZ
PZ2
Do not connect anything to this.
PG
PG
SD
SD
search engine
Ferrule part No.
With insulation
Without insulation
sleeve
sleeve
A 0,34-7
A 0,5-6
Blade terminal
Insulation cap
part No.
part No.
BT 0.75-7
VC 0.75
SF-JR/HR/JRCA/HRCA (with encoder)
PA
PAR
PB
PBR
PZ
PZR
5E
AG2
Crimping tool
model No.
CRIMPFOX 6
Crimping tool
model No.
NH 69
FR-JCBL