I/O Signal List - Mitsubishi Electric FR-A800 Series Instruction Manual

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

NOTE
• Refer to the MELSEC iQ-R, MELSEC-Q, or MELSEC-L CC-Link IE Field Network Master/Local Module User's Manual for the
detailed assignment methods for the link devices and link refresh.

5.21.2 I/O signal list

 Remote I/O (64 points (fixed))
*5
Device No.
RYn0
Forward rotation command
RYn1
Reverse rotation command
High-speed operation command (terminal
RYn2
RH function)
Middle-speed operation command
RYn3
(terminal RM function)
Low-speed operation command (terminal
RYn4
RL function)
Jog operation selection (terminal JOG
RYn5
function)
Second function selection (terminal RT
RYn6
function)
Current input selection (terminal AU
RYn7
function)
Selection of automatic restart after
instantaneous power failure (terminal CS
RYn8
function)
RYn9
Output stop (terminal MRS function)
Start self-holding selection (terminal STOP
RYnA
function)
RYnB
Reset (terminal RES function)
RYnC to
RYnF
Reserved
RY(n+1)0 to
RY(n+1)2
RY(n+1)3 to
Reserved
RY(n+1)F
RY(n+2)0
Monitor command
RY(n+2)1
Frequency setting command (RAM)
Frequency setting command (RAM,
RY(n+2)2
EEPROM)
RY(n+2)3
Torque command / torque limit (RAM)
Torque command / torque limit (RAM,
RY(n+2)4
EEPROM)
RY(n+2)5
Instruction code execution request
RY(n+2)6 to
Reserved
RY(n+3)9
RY(n+3)A
Error reset request flag
RY(n+3)B to
Reserved
RY(n+3)F
*1
These signals are set in the initial setting. Using Pr.180 to Pr.189, input signals assigned to the device numbers can be changed. (Refer to
521.)
*2
The signals are fixed. They cannot be changed using parameters.
*3
These signals are set in the initial setting. Using Pr.190 to Pr.196, output signals assigned to the device numbers can be changed. (Refer to
473.)
*4
Output signal can be assigned using Pr.313 to Pr.315. (Refer to
*5
"n" indicates a value determined by the station number setting.
Downloaded from
ManualsNet.com
Signal
*2
*2
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
search engine
Refer
*5
Device No.
to page
756
RXn0
Forward running
756
RXn1
Reverse running
756
RXn2
Running (terminal RUN function)
756
RXn3
Up to frequency (terminal SU function)
756
RXn4
Overload alarm (terminal OL function)
Instantaneous power failure (terminal IPF
756
RXn5
function)
Frequency detection (terminal FU
756
RXn6
function)
756
RXn7
Error (terminal ABC1 function)
756
RXn8
— (terminal ABC2 function)
756
756
RXn9 to
Reserved
RXnF
756
RX(n+1)0
Pr.313 assignment function (DO0)
RX(n+1)1
Pr.314 assignment function (DO1)
RX(n+1)2
Pr.315 assignment function (DO2)
RX(n+1)3 to
Reserved
RX(n+1)F
756
RX(n+2)0
Monitoring
756
RX(n+2)1
Frequency setting completion (RAM)
Frequency setting completion (RAM,
756
RX(n+2)2
EEPROM)
Torque command / torque limit setting
757
RX(n+2)3
completion (RAM)
Torque command / torque limit setting
757
RX(n+2)4
completion (RAM, EEPROM)
757
RX(n+2)5
Instruction code execution completed
RX(n+2)6 to
Reserved
RX(n+3)9
757
RX(n+3)A
Error status flag
RX(n+3)B
Remote station ready
RX(n+3)C to
Reserved
RX(n+3)F
page
473.)
Signal
*3
*3
*3
*3
*3
*4
*4
*4
5. PARAMETERS
5.21 CC-Link IE Field Network (FR-A800-GF)
1
2
3
Refer
to page
758
4
758
758
5
*3
758
*3
758
6
758
758
7
758
8
758
9
10
758
758
758
758
758
758
758
758
758
758
758
page
page
753

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents