Controller Abort Minor Errors (Code: 14, XX)
Code
Description
14,01
Not Used
14,02
Report: Attempt to raise
modeling base sensor
failed
14,03
Report: modeling base
sensor up when it
should be down.
14,04
Report: modeling base
sensor down when it
should be up.
Corrective Actions
Not Used
1. Cycle power
2. Check to see if the toggle bar is broken.
3. Check for obstructions preventing X or Y
movement
4. Check the substrate sensor bar is not
damaged. If so, replace bar.
5. Using LED's check to see if Z foam box
toggles when switch is activated. If not,
check foam sensor and/or Umbilical Cable.
6. Check for loose pins on J506-2, J506- 7,
J301-5, and J301-6. See
diagram" on page 129.
7. Using LED's check to see Z home box
toggles when switch is activated. If not,
check Z home switch and/ lower harness J8
pins 1,1 1,12. See
"Lower harness" on
page 133.
1. Cycle power.
2. Check the substrate sensor assembly for free
operation.
3. Check to see if the sensor arm is broken.
4. Check connector J506, pins 2 and 7 on the
I/O card.
5. Using LED's check to see Z foam box
toggles when switch is activated. If not,
check substrate sensor, sensor assembly
and/or lower harness.
1. Push the sensor assembly up if it is down.
2. Check to see if the tip-wipe brush is set too
high.
3. Run the FZ command using Tera Term -Verify
the sensor is being pushed all the way up.
4. Remove, clean and reinstall the substrate
sensor assembly.
"Umbilical cable
-90