Performing part based calibration for HP Designjet Color 3D with the HP
Designjet Diagnostics Software
1. Open HP Designjet 3D Diagnostic Software and select the current
modeler from the pull down menu.
2. Open Gantry Calibration Dialog box in HP Designjet 3D Diagnostic
Software
3. Set the X adjust value to 0.
4. In the Part Calibration section, there are six boxes: LEFT, RIGHT, FRONT,
REAR, LEFT FRONT and LEFT REAR. Set these values to 0.
5. Click on the green check mark to save the values.
6. Toggle the system power down switch.
7. Once the system displays Idle, press Maintenance>System>Test Parts
then select the test_XY_cal part.
8. When part is completed, remove from printer and let cool for five min-
utes.
9. Locate the filled circle, this indicates the front of the substrate, see
374
Figure 374: Locating the Filled Circle (B)
10. Using a digital caliper, measure and record the diameter of circle B
along the center line between A and C, see
NOTE: Reference letters are not actually "printed" on the part. If
needed, use the Part Measurement Equations sheet to record the
values. See
"Part Measurement Equations" on page 380.
Figure
Figure 375