Installing the XY table

1. Insert the zero gauge block into the gauge. See
2. Loosen the adjustment screw and slide the dial indicator assembly up or
down to set the 'zero' reading: The large hand should be on 0 and the
small hand on 5.
3. Tighten the adjustment screw (do not over tighten the screw) and recheck
the reading.
4. Remove the zero block gauge block from the fixture.
Figure 261: Tension gauge zero setting
Adjustment screw
Zero gauge block
5. Position the dial indicator on the top section of the Y-Drive belt at the
center point of the belt. See
Figure 262: Y-Drive Belt Tension Check
Y-Drive Belt clamp (one
on each side).
Figure 261.
Figure 262.
Dial Indicator position for Y-
Drive belt tension check.