Part Based Calibration; When To Perform Part Based Calibration; Performing Part Based Calibration For Hp Designjet 3D From The Service Calibration Menu (Firmware Version 9.1 Or Newer); Performing Part Based Calibration For Hp Designjet 3D From The Service Cal- Ibration Menu (Firmware Version 9.1 Or Newer) - HP Designjet 3D Service Manual

Hide thumbs Also See for Designjet 3D:
Table of Contents

Advertisement

Part Based Calibration

Required Tools
Set of basic service tools
6" digital calipers
HP Designjet 3D Diagnostic Software CD (Printer firmware versions
older than 9.1)
Part based calibration consists of building a part and then taking six
measurements - front, right, left, rear, left rear and left front. These
measurements are then entered using HP Designjet 3D Diagnostic Software.

When to Perform Part Based calibration

Part Based calibration needs to be performed after replacing the XY table
assembly. Part Based calibration is performed to eliminate any skewing in
the X and Y axes.
Performing part based calibration for HP Designjet 3D from the Service
Calibration menu (Firmware version 9.1 or newer)
1. While the printer is at Idle, enter standby mode by pressing the
Standby... button.
2. Enter the Service Calibration menu by pressing the following button
sequence on the display panel: 3,2,3,3,1. See
Figure 322: Service Calibration button sequence
Button 0
Button 1
Button 2
Button 3
3. Press the Reset Part Based Calibration button.
4. The printer will ask "Do you want to zero settings and reboot?" Press
Yes.
5. Reboot the printer.