4.0 Non-Code Errors - HP Designjet 3D Service Manual

Hide thumbs Also See for Designjet 3D:
Table of Contents

Advertisement

4.0 Non-Code Errors

A. "Build Error" displayed on LCD
B. Tip Depth Incorrect
C. "Corrupted Upgrade" displayed on LCD
D. "Carrier Invalid or Empty" displayed on LCD
E. Door Latch
F.
"Door Open" displayed on LCD
G. Download
H. Loss of Extrusion (LOE)
I.
Lights
J.
Material/Unload Error (failed to load/unload material)
K. Network Communications
L.
Pauses during build
M. Power Up/Boot
N. "Can't Find Home - Check Modeling Base" displayed on
LCD
O. Power Down
P.
System VERY slow to reach temperature
Q. Calibration issues
R. Z Calibration failure
S. Noise
A. "Build Error" displayed on LCD
1. Part stops building before
complete.
B. Tip depth is incorrect
1. Tip Depth is wrong (too deep
or above the modeling
base)
C. "Corrupted Upgrade" Displayed on LCD
1. Partial or bad model file sent to unit. - Check
and reprocess the STL and redownload
1. Run Z tip calibration.
2. Check and/or clean the Z foam sensor.
3. Replace the Z foam assembly and sensor
1. Verify the printer firmware CD is the correct
gender. (Same as the system)
2. Cycle power and try download again. If not
possible or fails again replace hard drive.
3. Verify the hard drive and the controller board
are gendered correctly.
-107

Advertisement