HP Designjet 3D Service Manual page 115

Hide thumbs Also See for Designjet 3D:
Table of Contents

Advertisement

Code
Description
14,1 17
A command failed while
modeling
14,1 18
Invalid cyclic redundancy
check
14,1 19
Operation already active Software error; will not be displayed
14,120
Invalid vector detected
14,121
Processor Exception
14,122
Processor halted
14,123
Watchdog timeout
14,124
Stack overflow
14,125
Runtime error
14,126
Operation active - try
again
14,127
Invalid gender
14,128
Invalid platform
Corrective Actions
1. Download CFG file - check error code
details.
2. Toggle failure - reference 14,129.
3. Check and reseat connectors/pins on J506
on the I/O card and J301 on the head
board.
4. Replace Toggle Head assembly.
5. Replace PDB (U8 chip failure).
Software error; will not be displayed
1. Reprocess the part and send again.
2. Reorient part and send again.
3. If the frequency of the error is greater than
once every three months, then replace the
SBC or hard drive.
1. Cycle power.
1. Cycle power.
1. Cycle power.
2. Check all cable connections including
thermocouples.
3. Escalate the case providing .cfg file.
1. Cycle power.
2. If problem persists, replace controller board.
1. Cycle power.
1. Cycle power.
1. Cycle power.
2. If problem persists, replace controller board.
1. Cycle power.
2. If problem persists, replace controller board.