19.9.9 IAP status codes

Table 235: IAP status codes summary
Status
Code
0
1
2
3
4
5
6
7
8
9
10
11

19.10 JTAG flash programming interface

Debug tools can write parts of the flash image to the RAM and then execute the IAP call
"Copy RAM to Flash" repeatedly with proper offset.

User manual

Mnemonic
CMD_SUCCESS
INVALID_COMMAND
SRC_ADDR_ERROR
DST_ADDR_ERROR
SRC_ADDR_NOT_MAPPED
DST_ADDR_NOT_MAPPED
COUNT_ERROR
INVALID_SECTOR
SECTOR_NOT_BLANK
SECTOR_NOT_PREPARED_
FOR_WRITE_OPERATION
COMPARE_ERROR
BUSY
Rev. 01 — 12 January 2006
Chapter 19: Flash memory
Description
Command is executed successfully.
Invalid command.
Source address is not on a word boundary.
Destination address is not on a correct boundary.
Source address is not mapped in the memory map.
Count value is taken in to consideration where
applicable.
Destination address is not mapped in the memory
map. Count value is taken in to consideration where
applicable.
Byte count is not multiple of 4 or is not a permitted
value.
Sector number is invalid.
Sector is not blank.
Command to prepare sector for write operation was
not executed.
Source and destination data is not same.
Flash programming hardware interface is busy.