C8 Maintenance 4. Cable Unit
Removal: Cable unit (M/C cable backward)
1. Move the Manipulator to the origin posture (0 pulse position).
2. Turn OFF the Controller.
3. Remove the following covers and plate.
For details, refer to C8 Maintenance: 3. Covers.
Arm #4 side covers (both sides)
Arm #3 cover
Arm #2 side covers (both sides)
Arm #1 center cover
Connector plate (M/C cable backward)
4. Remove the two air tubes inside the base.
5. Remove the two D-sub connectors.
6. Disconnect the cables from the base and disconnect the following
connectors.
Connectors: X11, X12, X14, BR010, BR011, X010, X020,
X040, LED, GS01, BT1
(Hold the clip to remove.)
7. Disconnect the following connectors.
RJ45 connector:
Hold the clip to remove.
F-sensor connector:
Open the clips on the both ends of the connector and pull it out.
228
Arm #4 maintenance cover (C8XL only)
Arm #3 maintenance cover
Arm #1 side covers (both sides)
Base maintenance cover
C Series Maintenance Manual Rev.2