6.
Remove the connectors.
Connectors: CN3, CN6
7.
Remove the battery board fixed to the plate.
Cross recessed head screws: 3-M3×6
Installation: Battery board
NOTE
When tightening hexagon socket head cap bolts, refer to the 2.4 Tightening Hexagon Socket
Head Cap Bolts.
1. Install the battery board to the plate.
Cross recessed head screws: 3-M3×6
Tightening torque: 0.45 ± 0.1 N·m
2. Connect the connectors to the battery board.
Connector: CN3, CN6
C Series Maintenance Manual Rev.2
C12 Maintenance 11. Replacing the Battery Unit
623