C4 Maintenance 4. Cable Unit
16. Wrap the end of the spring to the fixing plate with a wire tie. (a)
Temporally bind the cables to the Arm #4 cable fixing plate. (b)
Wire tie: AB150
Silicone sheet: 15 mm × 50 mm
Precautions for cable unit fixation to the plate
Place the silicone sheet on the plate as shown in the photo on
NOTE
the right (example).
silicone sheet.
17. Temporarily fix the Arm #4 cable fixing plate to the Arm #4.
Hexagon socket head cap bolt: 2-M4×10
18. Temporarily bind the cables coming from the Arm #4.
Wire tie: AB150
Mark tube: 46 mm
Precautions for cable unit fixation to the plate:
Pass the mark tube and the wire tie through the hole of the plate
NOTE
as shown in the right photo.
34
Fix the wire tie at the center of the
(b)