C4 Maintenance 4. Cable Unit
5. Secure the Arm #2 cable fixing plate and the cable unit.
Plate and spring
Cable unit and plate : Wire tie AB150, Mark tube 65 mm
Precautions for cable unit fixation to the plate:
NOTE
Pass the mark tube and the wire tie through the hole of the plate
as shown in the photo on the right.
When installing the cable unit, place the plate, the air tube, and
the cables as shown in the photo on the right (example), and then
fix the plate and the cable unit with a wire tie.
6. Insert the cable unit with the cable protection spring (ø 17.5) from the
Arm #4.
7. Wrap the end of the spring to the Arm #4 cable fixing plate with a
wire tie.
Wire tie: AB100 × 1
Number of turns of spring to fix: 3 turns
30
: Wire tie AB100
Plate
C Series Maintenance Manual Rev.2
Cable
Air tube