Toshiba GR200 Series Instruction Manual page 162

Centralized busbar protection ied
Hide thumbs Also See for GR200 Series:
Table of Contents

Advertisement

Setting (CH3) of CBP_OC(Function ID: 458B01)
Setting item
CH3
OC1-EN
OC1-Timer
OC1 (in DT)
OC1 (in IDMT)
OC1-DPR
TOC1
OC1-TMS-IEC
OC1-TMS-UK
OC1-TMS-IEEE
OC1-TMS-US
OC1-TMS-ORG
OC1
OC1-Rtimer
TOC1R
OC1-RTMS-IEEE
OC1-RTMS-US
OC1-RTMS-ORG
OC1-k
OC1-a
OC1-c
OC1-kr
OC1-b
OC1-UseFor
OC2-EN
OC2-Timer
OC2 (in DT)
OC2 (in IDMT)
OC2-DPR
TOC2
OC2-TMS-IEC
OC2-TMS-UK
OC2-TMS-IEEE
OC2-TMS-US
OC2-TMS-ORG
OC2
OC2-Rtimer
TOC2R
OC2-RTMS-IEEE
OC2-RTMS-US
OC2-RTMS-ORG
OC2-k
OC2-a
OC2-c
OC2-kr
OC2-b
OC2-UseFor
(CH4 to CH23 are omitted)
U
ni
Range
ts
Off / On
IEC-NI / IEC-VI / IEC-EI
IEEE-MI /IEEE-VI /IEEE-EI
-
UK-LTI/ US-CO2/ US-CO8
DT/ Original
0.02 - 50.00
-
0.02 - 5.00
-
% Drop-out/Pick-up ratio
10 - 100
0.00 - 300.00
s
0.010 - 50.000
-
0.010 - 50.000
-
0.010 - 50.000
-
0.010 - 50.000
-
0.010 - 50.000
-
DEF / DEP
-
0.00 - 300.00
s
0.010 - 50.000
-
0.010 - 50.000
-
0.010 - 50.000
-
0.00000 - 500.00000
-
0.00000 - 10.00000
-
0.00000 - 10.00000
-
0.00000 - 500.00000
-
0.00000 - 10.00000
-
Trip / Alarm
-
Off / On
IEC-NI / IEC-VI / IEC-EI
IEEE-MI /IEEE-VI /IEEE-EI
-
UK-LTI/ US-CO2/ US-CO8
DT/ Original
0.02 - 50.00
-
0.02 - 5.00
-
% Drop-out/Pick-up ratio
10 - 100
0.00 - 300.00
s
0.010 - 50.000
-
0.010 - 50.000
-
0.010 - 50.000
-
0.010 - 50.000
-
0.010 - 50.000
-
DEF / DEP
-
0.00 - 300.00
s
0.010 - 50.000
-
0.010 - 50.000
-
0.010 - 50.000
-
0.00000 - 500.00000
-
0.00000 - 10.00000
-
0.00000 - 10.00000
-
0.00000 - 500.00000
-
0.00000 - 10.00000
-
Trip / Alarm
-
- 148 -
Contents
Enabling switch for OC1 element in CH3
Delay type
Threshold in DT mode (multiple of CT 2nd rating)
Threshold in IDMT mode (multiple of CT 2nd rating)
Operating delay time (in DT mode)
Time multiplier in IEC inverse curve
Time multiplier in UK inverse curve
Time multiplier in IEEE inverse curve
Time multiplier in US inverse curve
Time multiplier in Original inverse curve
Reset delay type
Definite time reset delay
Dependent reset time multiplier in IEEE inverse
curve
Dependent reset time multiplier in US inverse curve
Dependent reset time multiplier in Original inverse
curve
User original curve coefficient
User original curve coefficient
User original curve coefficient
User original curve coefficient
User original curve coefficient
OC1 out. selected for either Trip or alarm
Enabling switch for OC2 element in CH3
Delay type
Threshold in DT mode (multiple of CT 2nd rating)
Threshold in IDMT mode (multiple of CT 2nd rating)
Operating delay time (in DT mode)
Time multiplier in IEC inverse curve
Time multiplier in UK inverse curve
Time multiplier in IEEE inverse curve
Time multiplier in US inverse curve
Time multiplier in Original inverse curve
Reset delay type
Definite time reset delay
Dependent reset time multiplier in IEEE inverse
curve
Dependent reset time multiplier in US inverse curve
Dependent reset time multiplier in Original inverse
curve
User original curve coefficient
User original curve coefficient
User original curve coefficient
User original curve coefficient
User original curve coefficient
OC2 out. selected for either Trip or alarm
6F2S1931 (0.20)
Default
setting
Notes
value
Off
DT
1.00
1.00
100
1.00
1.000
1.000
1.000
1.000
1.000
DEF
0.00
1.000
1.000
1.000
0.00000
0.00000
0.00000
0.00000
0.00000
Trip
Off
DT
1.00
1.00
100
1.00
1.000
1.000
1.000
1.000
1.000
DEF
0.00
1.000
1.000
1.000
0.00000
0.00000
0.00000
0.00000
0.00000
Trip
Centralized GRB200
(Soft: 030, 031, 032, 033, 034)