Toshiba GR200 Series Instruction Manual page 250

Centralized busbar protection ied
Hide thumbs Also See for GR200 Series:
Table of Contents

Advertisement

Signal (DataID)
3.7.7
Connection points in PLC logics in GCNT01
GCNT (Function ID: 540001)
Element ID
800E00ED5A
800E01EDE0
Signal monitoring points in GCNT01
GCNT (Function ID: 540001)
Element ID
000E001F41
800E001D58
800E001D5E
800E001D5F
800E001D60
800E001D54
800E001D5B
800E001D5C
800E001D5D
840E011E95
310E011D21
320E011D20
000E011F42
890E011EA2
830E011E8B
820E011E84
8A0E011E76
8B0E011E7B
000E011D91
 Mapping point in GCNT01
GCNT (Function ID: 540001)
Element ID
700E016D09
Note: In the table above, the user will only find Element IDs and their names for the 1
device, but a 2
have omitted the Element IDs and their names for the other devices to improve
readability. Use the rule described below when the user wishes to obtain the
Element IDs and their names for the other devices.
Rule: The same types of signal monitoring points are provided in every device;
Name
GCNT00IN_TMP_51
GCNT01_PLC_SGNL
Name
GCNT00_CCTRL_COUNTER
GCNT00_CH_EC_LCD
GCNT00_CH_EC_OWS
GCNT00_CH_EC_RCC
GCNT00_CH_EC_RMT
GCNT00_CH_SC_LCD
GCNT00_CH_SC_OWS
GCNT00_CH_SC_RCC
GCNT00_CH_SC_RMT
GCNT01_CC_SSCN
GCNT01_CNT_QLT
GCNT01_CNT_VAL
GCNT01_CORR_INS
GCNT01_CTR_SGUCN
GCNT01_EC_F_CSCN
GCNT01_EC_OK_CSCN
GCNT01_SLD_CSCN
GCNT01_SLF_CSCN
GCNT01_TMP_01
Name
GCNT01_CMM_REQ
and other devices are also provided in the GCNT function. We
nd
hence, the user can find the same ones for all of the other devices. For
example, when the user wishes to find the "GCNT01_CTR_SGUCN" point
for the 2
device, use the description of "GCNT02_CTR_SGUCN" in place
nd
- 236 -
Description
GCNT00IN_TMP_51
GCNT01 plc signal
Description
GCNT00 cmnctrl counter correction summarize
GCNT00 count change execute command by LCD
GCNT00 count change execute command by OWS(HMI)
GCNT00 count change execute command by RCC
GCNT00 count change execute command by Remote
GCNT00 count change select command by LCD
GCNT00 count change select command by OWS(HMI)
GCNT00 count change select command by RCC
GCNT00 count change select command by Remote
GCNT01 cancel success signal
GCNT01 count quality
GCNT01 count value
GCNT01 correction instruction
GCNT01 control logic stage(under selection)
GCNT01 execute command fail condition signal
GCNT01 execute command OK condition signal
GCNT01 selected condition signal
GCNT01 select fail condition signal
GCNT01 count change selected signal(stSeld) for SAS
Description
GCNT01 control request(Mapping data)
6F2S1931 (0.20)
Centralized GRB200
(Soft: 030, 031, 032, 033, 034)
st

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grb200

Table of Contents