Signal monitoring point
CBP_OC(Function ID: 458B01)
Element ID
82B0041B62
82B0051B62
82B0061B62
82B0071B62
82B0081B62
82B0091B62
82B0101B62
82B0111B62
82B0121B62
82B0131B62
82B0141B62
82B0151B62
82B0161B62
82B0171B62
82B0181B62
82B0191B62
82B0201B62
82B0211B62
82B0221B62
82B0231B62
82B0241B62
8100001BB1
8100011BB4
8100021BB7
8100031BBA
8100041BBD
8100051BB0
8100061BB3
8100071BB6
8100081BB9
8100091BBC
8100101BBF
8100111BB2
8100121BB5
8100131BB8
8100141BBB
8100151BBE
8100161BB1
8100171BB4
8100181BB7
8100191BBA
8100201BBD
8100211BB0
8100221BB3
Name
OC1.OPT-C_CH4
OC1.OPT-C_CH5
OC1.OPT-C_CH6
OC1.OPT-C_CH7
OC1.OPT-C_CH8
OC1.OPT-C_CH9
OC1.OPT-C_CH10
OC1.OPT-C_CH11
OC1.OPT-C_CH12
OC1.OPT-C_CH13
OC1.OPT-C_CH14
OC1.OPT-C_CH15
OC1.OPT-C_CH16
OC1.OPT-C_CH17
OC1.OPT-C_CH18
OC1.OPT-C_CH19
OC1.OPT-C_CH20
OC1.OPT-C_CH21
OC1.OPT-C_CH22
OC1.OPT-C_CH23
OC1.OPT-C_CH24
OC2-BLOCK_CH1
OC2-BLOCK_CH2
OC2-BLOCK_CH3
OC2-BLOCK_CH4
OC2-BLOCK_CH5
OC2-BLOCK_CH6
OC2-BLOCK_CH7
OC2-BLOCK_CH8
OC2-BLOCK_CH9
OC2-BLOCK_CH10
OC2-BLOCK_CH11
OC2-BLOCK_CH12
OC2-BLOCK_CH13
OC2-BLOCK_CH14
OC2-BLOCK_CH15
OC2-BLOCK_CH16
OC2-BLOCK_CH17
OC2-BLOCK_CH18
OC2-BLOCK_CH19
OC2-BLOCK_CH20
OC2-BLOCK_CH21
OC2-BLOCK_CH22
OC2-BLOCK_CH23
- 159 -
Description
OC1_CH4 protection operated (phase-C)
OC1_CH5 protection operated (phase-C)
OC1_CH6 protection operated (phase-C)
OC1_CH7 protection operated (phase-C)
OC1_CH8 protection operated (phase-C)
OC1_CH9 protection operated (phase-C)
OC1_CH10 protection operated (phase-C)
OC1_CH11 protection operated (phase-C)
OC1_CH12 protection operated (phase-C)
OC1_CH13 protection operated (phase-C)
OC1_CH14 protection operated (phase-C)
OC1_CH15 protection operated (phase-C)
OC1_CH16 protection operated (phase-C)
OC1_CH17 protection operated (phase-C)
OC1_CH18 protection operated (phase-C)
OC1_CH19 protection operated (phase-C)
OC1_CH20 protection operated (phase-C)
OC1_CH21 protection operated (phase-C)
OC1_CH22 protection operated (phase-C)
OC1_CH23 protection operated (phase-C)
OC1_CH24 protection operated (phase-C)
OC2_CH1 protection block command
OC2_CH2 protection block command
OC2_CH3 protection block command
OC2_CH4 protection block command
OC2_CH5 protection block command
OC2_CH6 protection block command
OC2_CH7 protection block command
OC2_CH8 protection block command
OC2_CH9 protection block command
OC2_CH10 protection block command
OC2_CH11 protection block command
OC2_CH12 protection block command
OC2_CH13 protection block command
OC2_CH14 protection block command
OC2_CH15 protection block command
OC2_CH16 protection block command
OC2_CH17 protection block command
OC2_CH18 protection block command
OC2_CH19 protection block command
OC2_CH20 protection block command
OC2_CH21 protection block command
OC2_CH22 protection block command
OC2_CH23 protection block command