Toshiba GR200 Series Instruction Manual page 63

Centralized busbar protection ied
Hide thumbs Also See for GR200 Series:
Table of Contents

Advertisement

Signal monitoring points
CBP_DIF (Function ID: 412B01)
Element ID
Name
8300401B67
DIFZD-IDSV
8400501B67
DIFZE-IDSV
8500601B67
DIFZF-IDSV
8000101B68
DIFZA-IDSV-A
8400201B68
DIFZB-IDSV-A
8800301B68
DIFZC-IDSV-A
8C00401B68
DIFZD-IDSV-A
8000501B68
DIFZE-IDSV-A
8400601B68
DIFZF-IDSV-A
8100101B69
DIFZA-IDSV-B
8500201B69
DIFZB-IDSV-B
8900301B69
DIFZC-IDSV-B
8D00401B69
DIFZD-IDSV-B
8100501B69
DIFZE-IDSV-B
8500601B69
DIFZF-IDSV-B
8200101B6A
DIFZA-IDSV-C
8600201B6A
DIFZB-IDSV-C
8A00301B6A
DIFZC-IDSV-C
8E00401B6A
DIFZD-IDSV-C
8200501B6A
DIFZE-IDSV-C
8600601B6A
DIFZF-IDSV-C
8000101B62
DIFZA-OPT-A
8400201B62
DIFZB-OPT-A
8800301B62
DIFZC-OPT-A
8C00401B62
DIFZD-OPT-A
8000501B62
DIFZE-OPT-A
8400601B62
DIFZF-OPT-A
8100101B63
DIFZA-OPT-B
8500201B63
DIFZB-OPT-B
8900301B63
DIFZC-OPT-B
8D00401B63
DIFZD-OPT-B
8100501B63
DIFZE-OPT-B
8500601B63
DIFZF-OPT-B
8200101B64
DIFZA-OPT-C
8600201B64
DIFZB-OPT-C
8A00301B64
DIFZC-OPT-C
8E00401B64
DIFZD-OPT-C
8200501B64
DIFZE-OPT-C
8600601B64
DIFZF-OPT-C
8000101C20
DIFZA-A
8400201C20
DIFZB-A
8800301C20
DIFZC-A
8C00401C20
DIFZD-A
8000501C20
DIFZE-A
Description
Differential current monitoring of Zone-D
Differential current monitoring of Zone-E
Differential current monitoring of Zone-F
Differential current monitoring of Zone-A (phase-A)
Differential current monitoring of Zone-B (phase-A)
Differential current monitoring of Zone-C (phase-A)
Differential current monitoring of Zone-D (phase-A)
Differential current monitoring of Zone-E (phase-A)
Differential current monitoring of Zone-F (phase-A)
Differential current monitoring of Zone-A (phase-B)
Differential current monitoring of Zone-B (phase-B)
Differential current monitoring of Zone-C (phase-B)
Differential current monitoring of Zone-D (phase-B)
Differential current monitoring of Zone-E (phase-B)
Differential current monitoring of Zone-F (phase-B)
Differential current monitoring of Zone-A (phase-C)
Differential current monitoring of Zone-B (phase-C)
Differential current monitoring of Zone-C (phase-C)
Differential current monitoring of Zone-D (phase-C)
Differential current monitoring of Zone-E (phase-C)
Differential current monitoring of Zone-F (phase-C)
DIFZA protection operated (phase-A)
DIFZB protection operated (phase-A)
DIFZC protection operated (phase-A)
DIFZD protection operated (phase-A)
DIFZE protection operated (phase-A)
DIFZF protection operated (phase-A)
DIFZA protection operated (phase-B)
DIFZB protection operated (phase-B)
DIFZC protection operated (phase-B)
DIFZD protection operated (phase-B)
DIFZE protection operated (phase-B)
DIFZF protection operated (phase-B)
DIFZA protection operated (phase-C)
DIFZB protection operated (phase-C)
DIFZC protection operated (phase-C)
DIFZD protection operated (phase-C)
DIFZE protection operated (phase-C)
DIFZF protection operated (phase-C)
DIFZA relay element operated (phase-A)
DIFZB relay element operated (phase-A)
DIFZC relay element operated (phase-A)
DIFZD relay element operated (phase-A)
DIFZE relay element operated (phase-A)
- 49 -
6F2S1931 (0.20)
Centralized GRB200
(Soft: 030, 031, 032, 033, 034)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grb200

Table of Contents