Epson E2C Series Manipulator Manual page 146

Scara robot
Table of Contents

Advertisement

Maintenance 6. Replacing the Reduction Gear Units (Joint #1)
(5) Remove the Joint #1 reduction gear unit
(6) Remove the Joint #1 motor unit from the
(7) Detach the oil seal from the Joint #1
(8) Remove the waveform generator from the
134
from the base.
To do so, unscrew the bolts from the
reduction gear flange.
reduction gear unit downward to remove it.
Joint #1 reduction gear unit.
To do so, unscrew the bolts from the motor
flange. Then, pull the motor unit upward
to remove it.
reduction gear, and then remove the
reduction gear flange.
Joint #1 motor.
There is a brass bushing in one of the
setscrew holes. Be careful not to lose it.
Then, pull the
Reduction gear
flange
Bushing
M4×6
Base
8-M4×12
3-M4×10
Motor flange
Reduction gear
unit
Oil seal
13-M3×15
Reduction
gear flange
M4×6
Waveform generator
E2C Rev.6

Advertisement

Table of Contents
loading