Custom U/f ratio

The user can define a U/f curve (output voltage as a function of frequency). This
custom ratio is used only in special applications where linear and squared U/f ratio
are not sufficient (e.g. when motor break-away torque needs to be boosted).
Voltage (V)
par. 2618
par. 2616
par. 2614
par. 2612
par. 2610
par. 2603
Note: The voltage and the frequency points of the U/f curve must fulfill the following
requirements:
2610
and
2611
WARNING! High voltage at low frequencies may result in poor performance or motor
damage (overheating).

Settings

Parameter
2605
2610...2618

Diagnostics

Fault
PAR CUSTOM U/F
Program features
par. 2611
<
2612
<
2614
<
2616
<
2613
<
2615
<
2617
Additional information
Custom U/f ratio activation
Custom U/f ratio settings
Additional information
Incorrect U/f ratio
Custom U/f ratio
par. 2613
par. 2615
<
2618
<
9907
f (Hz)
par. 2617
par. 9907