Parameters – complete descriptions
Index Name/Selection
4213
SETPOINT MAX
4214
FBK SEL
4215
FBK MULTIPLIER
4216
ACT1 INPUT
4217
ACT2 INPUT
4218
ACT1 MINIMUM
4219
ACT1 MAXIMUM
4220
ACT2 MINIMUM
4221
ACT2 MAXIMUM
4228
ACTIVATE
NOT SEL
DI1
DI2
DI3
DI4
DI5
DRIVE RUN
ON
TIMED FUNC 1
TIMED FUNC 2
TIMED FUNC 3
TIMED FUNC 4
DI1(INV)
DI2(INV)
DI3(INV)
DI4(INV)
DI5(INV)
4229
OFFSET
0.0...100.0%
4230
TRIM MODE
NOT SEL
PROPORTIONAL
DIRECT
Actual signals and parameters
Description
See parameter
4013
SETPOINT MAX.
See parameter
4014
FBK SEL.
See parameter
4015
FBK MULTIPLIER.
See parameter
4016
ACT1 INPUT.
See parameter
4017
ACT2 INPUT.
See parameter
4018
ACT1 MINIMUM.
See parameter
4018
ACT1 MAXIMUM.
See parameter
4020
ACT2 MINIMUM.
See parameter
4021
ACT2 MAXIMUM.
Selects the source for the external PID function activation signal. Parameter
4230
TRIM MODE must be set to NOT SEL.
No external PID control activation selected
Digital input DI1. 1 = active, 0 = inactive.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
Activation at drive start. Start (drive running) = active.
Activation at drive power-up. Power-up (drive powered) = active.
Activation by a timed function. Timed function 1 active = PID control active.
See parameter group
36 TIMED
See selection TIMED FUNC 1.
See selection TIMED FUNC 1.
See selection TIMED FUNC 1.
Inverted digital input DI1. 0 = active, 1 = inactive.
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
Defines the offset for the external PID controller output. When PID controller
is activated, controller output starts from the offset value. When PID
controller is deactivated, controller output is reset to the offset value.
Parameter
4230
TRIM MODE must be set to NOT SEL.
Value in percent
Activates the trim function and selects between the direct and proportional
trimming. With trimming it is possible to combine a corrective factor to the
drive reference. See section
No trim function selected
Active. The trimming factor is proportional to the rpm/Hz reference before
trimming (REF1).
Active. The trimming factor is relative to a fixed maximum limit used in the
reference control loop (maximum speed, frequency or torque).
FUNCTIONS.
Reference trimming
on page 101.
Def, FbEq
NOT SEL
0
1
2
3
4
5
7
8
9
10
11
12
-1
-2
-3
-4
-5
0
1 = 0.1%
NOT SEL
0
1
2