Battery; Leds - ABB ACS350 User Manual

Hide thumbs Also See for ACS350:
Table of Contents

Advertisement

Battery

A battery is only used in Assistant Control Panels that have the clock function
available and enabled. The battery keeps the clock operating in memory during
power interruptions.
The expected life for the battery is greater than ten years. To remove the battery, use
a coin to rotate the battery holder on the back of the control panel. Replace the
battery with type CR2032.
Note: The battery is NOT required for any control panel or drive functions, except
the clock.

LEDs

There is a green and a red LED on the front of the drive. They are visible through the
panel cover but invisible if a control panel is attached to the drive. The Assistant
Control Panel has one LED. The table below describes the LED indications.
Where
On the front of the drive.
If a control panel is
attached to the drive,
switch to remote control
(otherwise a fault will be
generated), and then
remove the panel to be
able to see the LEDs.
At the top left corner of
the Assistant Control
Panel
LED off
No power
Panel has no power or
no drive connection.
LED lit and steady
Green
Power supply on the
board OK
Red
Drive in a fault state. To
reset the fault, press
RESET from the control
panel or switch off the
drive power.
Green
Drive in a normal state
Red
Drive in a fault state. To
reset the fault, press
RESET from the control
panel or switch off the
drive power.
LED blinking
Green
Drive in an alarm state
Red
Drive in a fault state. To
reset the fault, switch off
the drive power.
Green
Drive in an alarm state
Red
-
Maintenance and hardware diagnostics