Jogging function uses constant speed 7 as jogging speed and acceleration/
deceleration ramp pair 2.
It is also possible to activate jogging function 1 or 2 through fieldbus. Jogging
function 1 uses constant speed 7 and jogging function 2 uses constant speed 6.
Both functions use acceleration/deceleration ramp pair 2.

Settings

Parameter
1010
1208
1208
2112
2205,
2207

Diagnostics

Actual values
0302
1401
1805
Program features
Additional information
Jogging activation
Jogging speed
/
1207
Jogging speed for jogging function 1/2 activated through fieldbus
Zero speed delay
2206
Acceleration and deceleration times
Acceleration and deceleration ramp shape time: Set to zero during the
jogging (i.e. linear ramp).
Additional information
Jogging 1/2 activation through fieldbus
Jogging function status through RO
Jogging function status through DO