Enter the motor data from the motor nameplate:
3
V
690 Y
400 D
660 Y
380 D
415 D
440 D
Cat. no
6312/C3
• motor nominal voltage (parameter 9905)
• motor nominal current (parameter 9906)
Allowed range: 0.2...2.0 · I
• motor nominal frequency (parameter 9907)
• motor nominal speed (parameter 9908)
• motor nominal power (parameter 9909)
Select the motor identification method (parameter 9910).
The default value 0 (OFF/IDMAGN) using the identification magnetization is suitable for
most applications. It is applied in this basic start-up procedure. Note however that this
requires that:
• parameter
9904
• parameter
9904
FLYSTART) or 5 (FLY + BOOST).
If your selection is 0 (OFF/IDMAGN), move to the next step.
Value 1 (ON) should be selected if:
- the operation point is near zero speed, and/or
- operation at torque range above the motor nominal torque over a wide speed range and
without any measured speed feedback is required.
If you decide to do the ID Run (value 1 (ON)), continue by following the separate instructions
given on page
OF THE MOTOR ROTATION
Start-up, control with I/O and ID Run
ABB Motors
motor
M2AA 200 MLA 4
IEC 200 M/L 55
No
Ins.cl. F
Hz
kW
r/min
A
cos
30
1475
32.5
0.83
50
50
1475
56
0.83
30
50
1470
34
0.83
30
30
1470
59
0.83
50
50
30
1475
54
0.83
35
59
0.83
1770
60
3GAA 202 001 - ADA
6210/C3
IEC 34-1
A
2N
is set to 1 (VECTOR: SPEED) or 2 (VECTOR: TORQ)
is set to 3 (SCALAR: FREQ), and parameter
54
in section
How to perform the ID Run
on page 49.
IP 55
IA/IN t E/s
380 V
supply
voltage
180
and then return to step
Note: Set the motor data to
exactly the same value as on
the motor nameplate. For
example, if the motor nominal
speed is 1440 rpm on the
nameplate, setting the value of
parameter
9908
MOTOR NOM
SPEED to 1500 rpm results in
the wrong operation of the drive.
9905
REM
PAR
9906
REM
PAR
9907
REM
PAR
9908
REM
PAR
9909
REM
PAR
2101
is set to 3 (SCALAR
DIRECTION
FWD
FWD
FWD
FWD
FWD