ABB ACS350 User Manual page 182

Hide thumbs Also See for ACS350:
Table of Contents

Advertisement

182
Parameters – complete descriptions
Index Name/Selection
DI2
DI3
DI4
DI5
COMM
DI1(INV)
DI2(INV)
DI3(INV)
DI4(INV)
DI5(INV)
2015
MIN TORQUE 1
-600.0...0.0%
2016
MIN TORQUE 2
-600.0...0.0%
2017
MAX TORQUE 1
0.0...600.0%
2018
MAX TORQUE 2
0.0...600.0%
2019
BRAKE CHOPPER
2020
BRAKE CHOPPER
INBUILT
EXTERNAL
Actual signals and parameters
Description
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
Fieldbus interface as the source for the torque limit 1/2 selection, i.e. control
word
0301
FB CMD WORD 1 bit 15. The control word is sent by the fieldbus
controller via the fieldbus adapter or embedded fieldbus (modbus) to the
drive. For the control word bits, see section
page 262.
Maximum torque limit 1 is defined by parameter
maximum torque limit 2 is defined by parameter
Note: This setting applies only for the DCU profile!
Inverted digital input DI1. 1 = parameter
0 = parameter
2018
MAX TORQUE 2 value.
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
Defines minimum torque limit 1 for the drive. See parameter
TORQUE SEL.
Value in percent of the motor nominal torque
Defines minimum torque limit 2 for the drive. See parameter
TORQUE SEL.
Value in percent of the motor nominal torque
Defines maximum torque limit 1 for the drive. See parameter
TORQUE SEL.
Value in percent of the motor nominal torque
Defines maximum torque limit 2 for the drive. See parameter
TORQUE SEL.
Value in percent of the motor nominal torque
Old parameter. Left out in sw version 2.51b and later. See parameter 2202.
Selects the brake chopper control. (Only in sw version 2.51b or later).
Internal brake chopper control.
Note: Ensure the brake resistor(s) is installed and the overvoltage control is
switched off by setting parameter
DISABLE.
External brake chopper control.
Note: The drive is compatible only with ABB ACS-BRK-X brake units.
Note: Ensure the brake unit is installed and the overvoltage control is
switched off by setting parameter
DISABLE.
DCU communication profile
2017
MAX TORQUE 1 and
2018
MAX TORQUE 2.
2017
MAX TORQUE 1 value.
2005
OVERVOLT CTRL to selection
2005
OVERVOLT CTRL to selection
Def, FbEq
2
3
4
5
7
on
-1
-2
-3
-4
-5
2013
MIN
-300
1 = 0.1%
2013
MIN
-300
1 = 0.1%
2014
MAX
300
1 = 0.1%
2014
MAX
300
1 = 0.1%
INBUILT
0
1