Actual signals

Actual signals
No.
Name/Value

01 OPERATING DATA

0101
SPEED & DIR
0102
SPEED
0103
OUTPUT FREQ
0104
CURRENT
0105
TORQUE
0106
POWER
0107
DC BUS VOLTAGE
0109
OUTPUT VOLTAGE
0110
DRIVE TEMP
0111
EXTERNAL REF 1
0112
EXTERNAL REF 2
0113
CTRL LOCATION
0114
RUN TIME (R)
0115
KWH COUNTER (R)
0120
AI1
0121
AI2
0124
AO1
0126
PID 1 OUTPUT
0127
PID 2 OUTPUT
0128
PID 1 SETPNT
0129
PID 2 SETPNT
0130
PID 1 FBK
0131
PID 2 FBK
0132
PID 1 DEVIATION
Description
Basic signals for monitoring the drive (read-only)
Calculated motor speed in rpm. A negative value indicates reverse
direction.
Calculated motor speed in rpm
Calculated drive output frequency in Hz. (Shown by default on the panel
Output mode display.)
Measured motor current in A. (Shown by default on the panel Output
mode display.)
Calculated motor torque in percent of the motor nominal torque
Measured motor power in kW
Measured intermediate circuit voltage in VDC
Calculated motor voltage in VAC
Measured IGBT temperature in °C
External reference REF1 in rpm or Hz. Unit depends on parameter
MOTOR CTRL MODE setting.
External reference REF2 in percent. Depending on the use, 100% equals
the maximum motor speed, nominal motor torque, or maximum process
reference.
Active control location. (0) LOCAL; (1) EXT1; (2) EXT2. See section
control vs. external control
Elapsed drive running time counter (hours). The counter can be reset by
pressing the UP and DOWN buttons simultaneously when the control
panel is in Parameter mode.
kWh counter. The counter can be reset by pressing UP and DOWN
buttons simultaneously when the control panel is in Parameter mode.
Relative value of analog input AI1 in percent
Relative value of analog input AI2 in percent
Value of analog output AO in mA
Output value of the process PID1 controller in percent
Output value of the PID2 controller in percent
Setpoint signal (reference) for the process PID1 controller. Unit depends
on parameter
4006
UNIT,
SET settings.
Setpoint signal (reference) for the PID2 controller. Unit depends on
parameter
4106
UNIT and
Feedback signal for the process PID1 controller. Unit depends on
parameter
4006
UNIT,
4007
settings.
Feedback signal for the PID2 controller. Unit depends on parameter
UNIT and
4107
UNIT SCALE settings.
Deviation of the process PID1 controller, i.e. the difference between the
reference value and the actual value. Unit depends on parameter
UNIT,
4007
UNIT SCALE and
on page 97.
4007
UNIT SCALE and
4027
4107
UNIT SCALE settings.
UNIT SCALE and
4027
4027
PID 1 PARAM SET settings.
FbEq
1 = 1 rpm
1 = 1 rpm
1 = 0.1 Hz
1 = 0.1 A
1 = 0.1%
1 = 0.1 kW
1 = 1 V
1 = 1 V
1 = 0.1°C
9904
1 = 0.1 Hz /
1 rpm
1 = 0.1%
Local
1 = 1
1 = 1 h
1 = 1 kWh
1 = 0.1%
1 = 0.1%
1 = 0.1 mA
1 = 0.1%
1 = 0.1%
-
PID 1 PARAM
-
-
PID 1 PARAM SET
-
4106
-
4006
Actual signals and parameters
143