ABB ACS350 User Manual page 75

Hide thumbs Also See for ACS350:
Table of Contents

Advertisement

How to select the monitored signals
Step
Action
1.
You can select which signals are monitored in the Output mode and how they
are displayed with group
detailed instructions on changing parameter values.
By default, the display shows three signals. The particular default signals
depend on the value of parameter
default value of parameter
the default for signal 1 is
defaults for signals 2 and 3 are always
respectively.
To change the default signals, select up to three signals from group
OPERATING DATA
Signal 1: Change the value of parameter
the signal parameter in group
parameter without the leading zero), e.g. 105 means parameter
Value 0 means that no signal is displayed.
Repeat for signals 2
2.
Select how you want the signals to be displayed: as a decimal number or a bar
graph. For decimal numbers, you can specify the decimal point location, or use
the decimal point location and unit of the source signal [setting (9 (DIRECT)].
For details, see parameter 3404.
Signal 1: parameter
Signal 2: parameter
Signal 3: parameter
3.
Select the units to be displayed for the signals. This has no effect if parameter
3404/3411/3418
Signal 1: parameter
Signal 2: parameter
Signal 3: parameter
4.
Select the scalings for the signals by specifying the minimum and maximum
display values. This has no effect if parameter
(DIRECT). For details, see parameters
Signal 1: parameters
Signal 2: parameters
Signal 3: parameters
34 PANEL DISPLAY
9902
APPLIC MACRO: For macros whose
9904
MOTOR CTRL MODE is 1 (VECTOR:SPEED),
0102
SPEED, otherwise
0104
to be shown.
3401
01 OPERATING DATA
(3408
SIGNAL2 PARAM) and 3
3404
OUTPUT1 DSP FORM
3411
OUTPUT2 DSP FORM
3418
OUTPUT3 DSP FORM.
is set to 9 (DIRECT). For details, see parameter 3405.
3405
OUTPUT1 UNIT
3412
OUTPUT2 UNIT
3419
OUTPUT3 UNIT.
3406
3406
OUTPUT1 MIN and
3413
OUTPUT2 MIN and
3420
OUTPUT3 MIN and
parameters. See page
74
0103
OUTPUT FREQ. The
CURRENT and
0105
TORQUE,
01
SIGNAL1 PARAM to the index of
(= number of the
0105
TORQUE.
(3415
SIGNAL3 PARAM).
3404/3411/3418
is set to 9
and 3407.
3407
OUTPUT1 MAX
3414
OUTPUT2 MAX
3421
OUTPUT3 MAX.
Display
LOC
PAR EDIT
for
3401 SIGNAL1 PARAM
OUTPUT FREQ
[103]
CANCEL
00:00
LOC
PAR EDIT
3408 SIGNAL2 PARAM
CURRENT
[104]
CANCEL
00:00
LOC
PAR EDIT
3415 SIGNAL3 PARAM
TORQUE
[105]
CANCEL
00:00
LOC
PAR EDIT
3404 OUTPUT1 DSP FORM
DIRECT
[9]
CANCEL
00:00
LOC
PAR EDIT
3405 OUTPUT1 UNIT
Hz
[3]
CANCEL
00:00
LOC
PAR EDIT
3406 OUTPUT1 MIN
0.0 Hz
CANCEL
00:00
LOC
PAR EDIT
3407 OUTPUT1 MAX
500.0 Hz
CANCEL
00:00
Control panels
75
SAVE
SAVE
SAVE
SAVE
SAVE