ALARM CODE
CAUSE
5029
Memory is not ready.
5030
Invalid request
5031
Drive is not ready for operation, e.g due to low DC
voltage.
5032
Parameter error
5040
Parameter download error. Selected parameter set
is not in current parameter backup file.
5041
Parameter backup file does not fit into memory.
5042
Parameter download error. Selected parameter set
is not in current parameter backup file.
5043
No start inhibit
5044
Parameter backup file restoring error
5050
Parameter upload aborted
5051
File error
5052
Parameter upload has failed.
5060
Parameter download aborted
5062
Parameter download has failed.
5070
Panel backup memory write error
5071
Panel backup memory read error
5080
Operation is not allowed because drive is not in
local control mode.
5081
Operation is not allowed because of active fault.
5082
Operation is not allowed because override mode is
enabled.
5083
Operation is not allowed because parameter lock is
on.
5084
Operation is not allowed because drive is
performing task.
5085
Parameter download from source to destination
drive has failed.
5086
Parameter download from source to destination
drive has failed.
5087
Parameter download from source to destination
drive has failed because parameter sets are
incompatible.
5088
Operation has failed because of drive memory
error.
5089
Download has failed because of CRC error.
5090
Download has failed because of data processing
error.
5091
Operation has failed because of parameter error.
5092
Parameter download from source to destination
drive has failed because parameter sets are
incompatible.
WHAT TO DO
Retry.
Contact your local ABB representative.
Check input power supply.
Contact your local ABB representative.
Perform upload function before download.
Contact your local ABB representative.
Perform upload function before download.
Check that file is compatible with drive.
Retry parameter upload.
Contact your local ABB representative.
Retry parameter upload.
Retry parameter download.
Retry parameter download.
Contact your local ABB representative.
Contact your local ABB representative.
Switch to local control mode.
Check cause of fault and reset fault.
Check parameter
1602
PARAMETER LOCK
setting.
Wait until task is completed and retry.
Check that source and destination drive types
are same, i.e. ACS350. See drive type
designation label.
Check that source and destination drive type
codes are same. See drive type designation
label.
Check that source and destination drive
information are same. See parameters in group
33
INFORMATION.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Check that source and destination drive
information are same. See parameters in group
33
INFORMATION.
277
Fault tracing