13.8 Control Register Details

Address
0x5300
T16E_CA
PWM Timer Compare Data A Register
0x5302
T16E_CB
PWM Timer Compare Data B Register
0x5304
T16E_TC
PWM Timer Counter Data Register
0x5306
T16E_CTL
PWM Timer Control Register
0x5308
T16E_CLK
PWM Timer Input Clock Select Register
0x530a
T16E_IMSK PWM Timer Interrupt Mask Register
0x530c
T16E_IFLG
PWM Timer Interrupt Flag Register
The PWM & capture timer registers are described in detail below. These are 16-bit registers.
Note: When data is written to the registers, the "Reserved" bits must always be written as 0 and not 1.
S1C17001 TECHNICAL MANUAL
Table 13.8.1: PWM & capture timer register list
Register name
EPSON
13 PWM & CAPTURE TIMER (T16E)
Function
Compare data A setting
Compare data B setting
Counter data
Timer mode setting and timer RUN/STOP
Prescaler output clock selection
Interrupt mask setting
Interrupt occurrence status display/resetting