0X4104: Uart Control Register (Uart_Ctl) - Epson S1C17001 Technical Manual

Cmos 16-bit single chip microcontroller
Table of Contents

Advertisement

0x4104: UART Control Register (UART_CTL)

Register name Address
Bit
UART Control
0x4104
D7
Register
(8 bits)
D6
(UART_CTL)
D5
D4
D3–2 –
D1
D0
D7
Reserved
D6
REIEN: Receive Error Interrupt Enable Bit
Permits interrupt requests to the ITC when a receive error occurs.
1 (R/W): Permitted
0 (R/W): Prohibited (default)
Set this bit to 1 to process receive errors using interrupts.
D5
RIEN: Receive Buffer Full Interrupt Enable Bit
Permits interrupt requests to the ITC caused when the received data quantity in the receive data buffer
reaches the quantity specified in RBFI (D1).
1 (R/W): Permitted
0 (R/W): Prohibited (default)
Set this bit to 1 to read receive data using interrupts.
D4
TIEN: Transmit Buffer Empty Interrupt Enable Bit
Permits interrupt requests to the ITC caused when transmission data in the transmit data buffer is sent
to the shift register (i.e. when data transmission begins).
1 (R/W): Permitted
0 (R/W): Prohibited (default)
Set this bit to 1 to write data to the transmit data buffer using interrupts.
D[3:2]
Reserved
D1
RBFI: Receive Buffer Full Interrupt Condition Setup Bit
Sets the quantity of data in the receive buffer to generate a receive buffer full interrupt.
1 (R/W): 2 bytes
0 (R/W): 1 byte (default)
If receive buffer full interrupts are permitted (RIEN = 1), the UART outputs an interrupt request pulse
to the ITC when the quantity of received data specified by RBFI is loaded into the receive data buffer.
If the RBFI bit is 0, an interrupt request pulse is output as soon as one item of received data is loaded
into the receive data buffer (when the RDRY flag (D1/UART_ST register) is set to 1). If RBFI is 1, an
interrupt request pulse is output as soon as two items of received data are loaded into the receive data
buffer (when the RD2B flag (D3/UART_ST register) is set to 1).
D0
RXEN: UART Enable Bit
Permits data transfer by the UART.
1 (R/W): Permitted
0 (R/W): Prohibited (default)
Set RXEN to 1 before starting UART transfers. Setting RXEN to 0 will stop data transfers. Set the
transfer conditions while RXEN is 0.
Preventing transfers by writing 0 to RXEN also clears transfer data buffers.
S1C17001 TECHNICAL MANUAL
Name
Function
reserved
REIEN
Receive error int. enable
RIEN
Receive buffer full int. enable
TIEN
Transmit buffer empty int. enable
reserved
RBFI
Receive buffer full int. condition
RXEN
UART enable
EPSON
Setting
Init. R/W
1 Enable
0 Disable
1 Enable
0 Disable
1 Enable
0 Disable
1 2 bytes
0 1 byte
1 Enable
0 Disable
18 UART
Remarks
0 when being read.
0
R/W
0
R/W
0
R/W
0 when being read.
0
R/W
0
R/W
229