Item
Mounting position
Applicable base unit
Input power supply
Input frequency
Input voltage distortion
Max. input apparent
power
Inrush current
5VDC
Rated output
current
24VDC
Overcurrent
5VDC
*1
protection
24VDC
Overvoltage
5VDC
*1
protection
24VDC
Efficiency
Dielectric withstand
voltage
Noise durability
Insulation resistance
Power indicator
Terminal screw size
Applicable wire size
Applicable solderless
terminal
Applicable tightening
torque
H
External
W
dimensions
D
Weight
Allowable momentary
power failure time
*1
For the descriptions of the specification items, refer to Page 213, Section 7.2.2.
210
A61P
100VAC to 120VAC
(85VAC to 132VAC)
200VAC to 240VAC
(170VAC to 264VAC)
Within 5% (
160VA
8A
8.8A or more
5.5 to 6.5V
Between AC external terminals and ground, 1500V AC, 1 minute
Between DC external terminals and ground, 500V AC, 1 minute
By noise simulator of 1500Vp-p noise voltage, noise width 1µs, and 25 to 60Hz
Between AC external terminals and ground, 5M or higher by 500VDC insulation resistance tester
0.98 kg
Performance Specifications
A61PN
Power supply module mounting slot
QA6B
+10%
-15%
+10%
-15%
50/60Hz ±5%
Page 103, Section 4.8.1)
*1
20A, 8ms or less
65% or more
noise frequency
LED indication of power supply
M4 × 0.7 × 6
0.75 to 2mm
R1.25-4, R2-4
RAV1.25, RAV2-4
78 to 118N•cm
250mm
55mm
121mm
0.75 kg
20ms or less
A62P
(15.6VDC to 31.2VDC)
155VA
100A, 1ms or less
5A
0.8A
5.5A or more
1.2A or more
5.5 to 6.5V
By noise simulator of
500Vp-p noise voltage,
noise width 1µs, and 25 to
60Hz noise frequency
2
0.94 kg
A63P
+30%
24VDC
-35%
65W
8A
8.5A or more
5.5 to 6.5V
0.8 kg
1ms or less